MiniSplitUV Model UV-30DL improves air quality and fights biological contamination
inside the air handling system. It extends the life of the air system and reduces maintenance
costs.
IMPORTANT!
Only qualifi ed technicians should install this product
Install in accordance with relevant building codes
Read instructions carefully including safety warnings
WARNING: Never expose eyes or skin to UVC light from any source. Looking
directly at the UVC light may casue permanent eye damage or blindness. Never
operate the UV-30 DL MiniSplitUV in an open area and in view of any person.
Installation Notes
MiniSplitUV is used for mini split systems and other limited space applications. Because
space is tight the best place for mounting the UV lights is usually inside the supply vent with
the light shining onto the blower wheel (which is prone to the worst mold growth).
Cutaway view of typical MiniSplit UV® installation in mini split
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT BEFORE SERVICING
Orient the UV lamps so that the light shines into the air system, not into the room.
Parts Included:
A
UV Lamps
B
Lamp Clips
C
Ballast Assy
D
120V Plug
E
Power Harness
F
Zip Ties
G
Adhesive Strips
H
Air Flow Sensor
I
UV Warning Sticker
WARNING
IMPORTANT!
Air System Preparation
1. Remove cover.
2b. For systems with non-removable
drain pan, remove louvers and baffl es
to access the area behind
UV Lamp Mounting
1. Determine the best location
for the UV lamp clips and clean
that area with an alcohol wipe.
Slide the mounting brackets
onto the ends of the UV lamps.
IMPORTANT!
Rotate the lamp so the warning sticker is visible and the UV light shines on
blower wheel and mold prone areas,
2a. Detach drain pan to access the
area behind it.
3. Drill holes to pass lamp cables through to
back of unit as needed.
2. Peel off paper from the adhesive backing on
the mounting brackets. Press the lamp with lamp
clips fi rmly in place about 2" from blower wheel.
NOT INTO THE ROOM
.
3. Pass the UV lamp cables through to
the back of the AC system.
P/N 780109300 RevA

Advertisement

loading

Summary of Contents for Field Controls MiniSplitUV UV-30DL

  • Page 1 Air System Preparation 1. Remove cover. 2a. Detach drain pan to access the area behind it. Installation & Operation Manual MiniSplitUV Model UV-30DL improves air quality and fights biological contamination inside the air handling system. It extends the life of the air system and reduces maintenance costs.