Namron Panelovn Zigbee Instruction Manual
Important: Read All Instructions Prior to Installation
Function introduction
Segment digital display
Safety & Warnings
• DO NOT install with power applied to device.
• DO NOT expose the device to moisture.
1. Product Data
Radio Frequency
Operation Mode
Measurement range
Set Temperature Range
Hysterersis
Ambient Temperature
• The Zigbee heating panel is a wireless heating device, which complies to Zigbee 3.0 wireless protocol
standards. The thermostat has 3 operation modes which can be controlled manually and locally or through
remote controlled through Zigbee gateway controller.
• All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible
control systems.
• Operation Modes: OFF, MANUAL,AUTO
• Measurement range: 0°C to +60°C
• WARNING: Electrical power must be switched off during installation
button
button
2.4GHz
OFF, MANUAL,AUTO
0°C to +60°C
5°C to 35°C
0.5°C to 2°C
0°C to 40°C (during operation)
Revised 04.01.2022
OK button

Advertisement

loading

Summary of Contents for Namron Panelovn Zigbee

  • Page 1 Namron Panelovn Zigbee Instruction Manual Revised 04.01.2022 Important: Read All Instructions Prior to Installation Function introduction button Segment digital display OK button button Safety & Warnings • DO NOT install with power applied to device. • DO NOT expose the device to moisture.
  • Page 2 2. Basic Function Introduction 2.1 Switch Operation modes Short press “OK” button to switch operation modes. Manual: (”MA”), the temperature can be set by APP and manually. After switch from another mode to this mode, icon will flash slowly for 5 seconds then the display will show the set temperature. Auto: (”AU”), only when the device is added to a Zigbee network, the temperature of a time period can be set through APP.
  • Page 3 Display the sensing room temperature of the temperature sensor head, when the sensing room temperature is over 50°C, the display will show 50°C, when the sensing room temperature is lower than 0°C (including the situation that the temperature sensor head falls off or short circuit), the display will show error indication: E1, and the display will Short press “-”...
  • Page 4 If set as “last status”, device will go to the status before power failure after power on again. If set as “default”, device will go to default mode after power on again. This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat Cluster (0x0201).
  • Page 5 This is the firmware version number of the application read-only INT8U , StackVersion 0x0002 read-only HWVersion INT8U , 0x0003 Hardware version 1 read-only string, ManufacturerName 0x0004 read-only “NAMRON AS” ModelIdentifier string, 0x0005 “5401392 & 5401396”/“5401393 & 5401397”/“5401394 & 5401398”/“5401395 & 5401399” read-only...
  • Page 6 DateCode string, 0x0006 NULL read-only PowerSource ENUM8, 0x0007 read-only Device power supply, fixed value 0x01 Mains (single phase) GenericDevice-Class ENUM8, 0x0008 0XFF read-only GenericDevice-Type ENUM8, 0x0009 0XFF read-only ProductCode octstr 0x000A read-only ProductURL string, 0x000B read-only NULL Sw build id string, 0x4000 6.9.1.0_r4...
  • Page 7 Remove Scene 0x02 Removes a scene from the scene table. Remove All Scenes 0x03 Removes all scenes that belong to a particular group. Store Scene 0x04 Stores the device’s current state as a scene or updates a previously stored scene accordingly Recall Scene 0x05 Reverts the device’s current state using the values from the previously...
  • Page 8 Enum8, ControlSequenceOfOperation 0x001B reportable Set device supported operation type, here only supports Heating Only(0x02) Enum8, System Mode 0x001C reportable System operation mode, supports 0x00(off) 0x04(heat) Map16, HVAC relay state/ ThermostatRunningState 0x0029 read-only, Indicates the relay on/off status, here only supports bit0( Heat State) reportable Enum8, StartOfWeek...
  • Page 9 Command supported: Command Description Setpoint Raise/Lower Increase or decrease the set temperature according to current mode, unit is 0.1ºC 0x0000 Note: only Dry mode and Manual mode can be configured through this attribute. SetWeeklySchedule The time period setting under Auto mode. Number of Transitions for Sequence, it must be 4, which means 4 time points should be set.
  • Page 10 RMSCurrent int16U , 0x0508 Valid current of single phase, unit is A reportable, read-only ActivePower int16S , 0x050B Valid power of single phase, unit is W reportable read-only ACVoltageMultiplier int16U, 0x0600 0x01 read-only ACVoltageDivisor 0x0a int16U, 0x0601 used together with above attribute, real displayed voltage= RMSVoltage* read-only ACVoltageMultiplier/ACVoltageDivisor int16U,...
  • Page 11 Attributes supported: Type Description Attribute TemperatureDisplayMode ENUM8, 0x0000 0x00 Temperature in °C only support reportable KeypadLockout ENUM8, 0x0001 0x00 No lockout reportable 0x01 - 0x05 lockout 3.3 Application Endpoint #242 GreenPower Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post@namron.com...