This instruction manual is for use by an authorized service technician
to install an Atwood – hydro flame™ furnace. Should you require
further information, contact your dealer or Atwood Mobile Products
LLC
This furnace design is certified for installation in recreation vehicles as
a MSP Category III furnace. Follow this installation instruction to insure
safe operation of the furnace. Failure to install furnace according to this
installation instruction nullifies the furnace warranty.
TO THE INSTALLER:
TO THE CONSUMER:
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety
hazards obey all safety messages following these
symbols
WARNING
Avoid possible injury or
death
WARNING
FIRE OR EXPLOSION
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
Extinguish any open flame.
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container
or source.
Do not touch any electrical switch, or use
any phone or radio in the vehicle.
Do not start the vehicle's engine or electric
generator.
Contact the nearest gas supplier or qualified
service technician for repairs.
If you cannot reach a gas supplier or
qualified service technician, contact the
nearest fire department.
Do not turn on the gas supply until the gas
leak(s) has been repaired.
A qualified Service Technician
Service Center or gas supplier must perform
installation and service.
LEAVE THIS MANUAL
WITH THE APPLIANCE.
RETAIN THIS MANUAL FOR
FUTURE REFERENCE.
CAUTION
Avoid possible injury
and/or property damage
Installation of this appliance must be in accordance with the written
instructions provided in this manual. No agent, representative or
employee of Atwood or other person has the authority to change,
modify or waive any provision of the instructions contained in this
manual.
Avoid possible injury or death
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to the
installation instructions and/or owner's manual provided with this
appliance. A qualified installer, service agency or the gas supplier must
perform installation and service.
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Be sure the furnace and all ignition systems are "off" during any type of
refueling and while vehicle is in motion or being towed.
CRITICAL INSTALLATION WARNINGS
DO NOT install furnace on material that restricts return air, like
carpet or any soft material such as vinyl.
DO NOT install furnace where clearance to combustibles cannot
be maintained.
DO NOT modify furnace or intake or exhaust vents in any way.
DO NOT alter furnace for a positive grounding system.
DO NOT hi pot furnace unless electronic ignition system (circuit
board) has been disconnected.
DO NOT use battery charger to supply power to DC model
furnace even when testing.
DO NOT use 120-volt AC current with DC models.
DO NOT use furnace cabinet area as a storage compartment.
DO NOT vent furnace with venting system serving another
appliance.
DO NOT vent furnace to an outside enclosed porch area.
DO NOT use for temporary heating of buildings or structures
under construction.
Protect installation materials from degrading air and flue exhaust
systems.
Protect furnace electrical components from water.
Compartments must be closed when in operation.
Should the gas supply fail to shut off during operation or
overheating occurs, shut the gas valve off to the furnace before
shutting off electrical supply.
DO NOT use this furnace if any part has been under water.
DO NOT use petroleum or citrus type cleaner on plastic parts, as
damage may occur.
1
Literature number 31970
hydro flame™
AFS Series Furnaces Models
AFSD12, AFSD16, AFSD20
Technical Installation Manual
WARNING
WARNING
FOR YOUR SAFETY
WARNING
AFSAD12
Effective 8/15

Advertisement

Table of Contents
loading

Summary of Contents for Atwood hydro flame AFS Series

  • Page 1 WARNING This instruction manual is for use by an authorized service technician to install an Atwood – hydro flame™ furnace. Should you require Installation of this appliance must be in accordance with the written further information, contact your dealer or Atwood Mobile Products instructions provided in this manual.
  • Page 2: Table Of Contents

    IGNITION CONTROL DIAGNOSTIC CODES ......7 PERSONAL INJURY WIRING AND LADDER DIAGRAM .......... 8 All sheet metal edges are sharp care should be taken when handling or brushing up against them. MODEL NOMENCLATURE WARNING CARBON MONOXIDE POISONING Atwood Cabinet Voltage Input Style Valve Model Furnace...
  • Page 3: Clearance To Combustibles

     All models can be installed in either a horizontal or vertical position Horizontal installs must have the gas line positioned on top, vertical installs must have vent located at the floor and gas line on the right side.  Always install furnace exhaust system through an exterior wall.
  • Page 4: Flexible Ducting Systems

     DO NOT mix assemblies with other units, each model has a *Note the table is for minimum requirements and should in most cases specific vent baffle size to operate correctly, see sticker on vent allow the unit to operate correctly. If unit burner cycles on and off on assembly.
  • Page 5: Standard Door Installation

     To prevent moisture from entering inside of coach wall, apply RTV type sealant to the back of the vent panel extension before installing through wall into furnace.  Vents are designed to allow water drainage when installed correctly. Use of foil tape as alternate sealing method is acceptable Locate were furnace will be installed and cut a hole opening as Locate the furnace vent cutout location.
  • Page 6: Propane Gas Connection

    FIRE OR EXPLOSION Never check for leaks with an open flame. Turn on the gas and apply Atwood Mobile Products highly recommends the use of an electronic soapy water or leak detect solution to all joints to see if bubbles are (solid-state) converter with clean power output.
  • Page 7: Thermostat Installation

    OPERATING INSTRUCTIONS Table 2 OVERCURRENT PROTECTION *Not More Than Seven Wires Per Harness WARNING **Not More Than Three Wires Per Harness FIRE OR EXPLOSION AWG OR SAE Maximum Ampacity Maximum Ampacity Conductor Size at Conductor at Conductor Do not operate furnace while vehicle is in motion or being (Gage) Insulation Insulation...
  • Page 8: Wiring And Ladder Diagram

    WIRING AND LADDER DIAGRAM...
  • Page 12 Figure 1 Large Paddle Kit 31093 Figure 2 Small Paddle Kit 31094 Figure 4 Valve Kit 31096 Figure 3 Valve Kit 31098 Figure 6 Electrode Adjustment Figure 5 Valve Kit 31097...
  • Page 13 Aucun agent, de représentant ou d'employé Cette conception de la fournaise a été certifiée pour l'installation dans Atwood ou toute autre personne n'a le pouvoir de changer, modifier ou un véhicule récréatif comme une fournaise de MSP catégorie III.
  • Page 14: Modèle De Nomenclature

    Toutes les tôles sont coupantes il faut veiller lors de manipulations et/ou brossage contre eux. Four Taille de Tension D'entrée Style Vanne Modèle Atwood coffret Type AVERTISSEMENT S = petit D = 12 1 = LP 1 = porte SA = petit...
  • Page 15: Four Général Installations

     Sol National Electrical Code ANSI/NFPA 70 ou CSA C22.1, partie 1  Parc remorques ANSI 119,5 Four général INSTALLATIONS  Tous les modèles peuvent être installés dans une ou l'autre horizontale ou verticale que horizontale installe doit avoir la conduite de gaz, placée sur le dessus, installe verticaux doit avoir évent situé...
  • Page 16: Décharge Et Conduits

    AIR FLOW VÉRIFIER  Appareil est testé à une élévation de température tel que spécifié DÉCHARGE ET CONDUITS sur la plaque signalétique. Après que l'installation du four et Modèle Zone de décharge requis conduit du système est terminée, pour obtenir une élévation de AFSA (12) GRILLE avant ou 15 à...
  • Page 17: Petit Vent Installer Ation

    NE sont pas trou surdimensionné – cours dimensionnement peut Insert fourneau d'à l'intérieur de l'autocar, aligner le trou du mur entraîner une fuite d'eau. avec évent dans la fournaise. Aucun dégagement autour de la découpe d'admission air pour Installation de ventilation, panneau d'évent de prolongation doit meilleure condition d'étanchéité.
  • Page 18: Gril Intérieur

    Locate étaient four sera installé et couper un ouverture tel qu'illustré à travers la paroi du trou où l'unité doit être installée. Four et composants doivent être protégés des outils de construction et des débris lors de l'installation. RTV s'appliquent à dos entier d'étanchéité bride de lunette, créant un joint complet Fourneau de tirer vers l'avant par découpe environ 1"...
  • Page 19: Branchements Électriques

    + 12 volts (Thermostat) BLOC D'ALIMENTATION Thermostat bleu -12 volts (Thermostat) • Atwood Mobile Products recommande fortement l'utilisation d'un Câblage pour thermostat à l'aide de 22 AWG minimum du fil torsadé. convertisseur électronique (transistor) avec une puissance propre. • Cela garantira une vie prolongée du moteur au-delà des applications Tout le câblage doit être installé...
  • Page 20: Fermer Unité

    • Au moment du tir initial de ce four, un brûlage des excédents d'huile restant du procédé de fabrication peut causer fumer ou les vapeurs pendant 5 à 10 minutes.  Remarque : si le four doit lock-outer, le ventilateur s'éteignent en 90 secondes et reste inactif jusqu'à...

Table of Contents