DIP-SW SETTING
Remote controller address setting (SW50)
z
A number of indoor units can be operated at the same time using a single remote controller.
Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
(See the following table.)
The DIP switches are normally set to make the unit number 00.
Remote controller address
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
JUMPER WIRE SETTING
JM40, 41 setting prohibited
z
Fan delay setting (JM42)
z
When the indoor unit is stopped while operating in conjunction with auxiliary heater, the indoor unit
fan operation will continue for one minute.
JM 3 / JM 42
Connect
Disconnect
(  . . .Factory setting)
DIP switch No.
1
2
3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
(  . . .Factory setting)
JM state
Invalid
Valid
- (01 - 29) -
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON