Power Supply CBA Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F602) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
J361
C1103
GND
C1101
C1102
J160
P-ON+21V
Q1103
L1104
L1102
Q1101
C1118
C1119
C1115
C1116
C1114
D1104
J168
R1125
VLED1
J357
R1123
GND
R1124
R1126
D1103
R1127
R1106
R1107
R1101
R1105
J264
BL-SW
C1105
R1103
C1112
R1102
C1121
C1104
C1106
J263
PWM1
R1109
R1110
C1107
R1108
R1111
R1112
C1111
R1132
J359
GND
R1131
R1129
R1130
J169
ILED1
CAUTION ! :
2.5A 250V
ATTENTION : Utiliser un fusible de rechange de même type de 2.5A, 250V.
C657
C1220
R657
R655
C1203
C653
C658
C666
C1201
R654
C1216
C1202
C660
P-ON+21V
R1117
J159
C1214
R1217
R658
GND
J364
C1218
R1216
Q653
Q1203
R1116
R669
C652
R667
D661
R674
C659
R660
Q1201
C1217
L1202
R659
C1215
L1204
D1102
D658
R1113
C1219
C1108
D652
JS1201
C639
L1203short
D1204
L1203
J262
R1225
D1202
LDR1
J261
R1223
C1208
R1104
R1213
SOURCE1
D1203
D654A
J166
D658A
AMP+13V
R1224
D1106
C654
C1109
J163
R1227
R1118
R1226
AMP+13V
C1221
R1204
R1207
R1205
D1206
D654
J256
C1205
R690
C1209
C1113
EN2
R1218
D653
C1212
R1203
C661
C638
C1110
R1202
R1120
D664
C655
C1204
R673
Q656
C1206
R670
C1213
R1209
R1206
J255
R672
PWM2
R1208
R1219
C1210
ALL+3.3V
C665
R1121
R1220
R671
C1207
R1232
C663
R662 R663
R1211
R1212
C1211
C668
R1231
R1221
R1229
R1230
R682
R680
R1128
R681
R1228
R1201
BA4GP0F0102 1
For continued protection against risk of fire,
replace only with same type 2.5A, 250V fuse.
J366
GND
J369
GND
R609
IC601
R661
D609A
Q602
C617
J162
R608
R606
C608
R607
R668
C609
D605
R612
Q621
R613
D608A
R675
R622
C607
C622
D610
D607A
C621
C610
C606
R604
R623
C623
C603
R621
D623
D621
Q601
T601
D606A
R651
D656A
D657
J167
R694
R652
R656
Q650
J250
C604
P-ON-H2
GND
J351
C651
R601
10-20
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
C618
R614
R610
+B
JS605
D604
+B
JS604
R603
+B
JS603
R602
D603
C613
FG
J602
C612
C614