Download Print this page

Amana AMH8 Technical Manual page 10

Hide thumbs Also See for AMH8:

Advertisement

PRODUCT DESIGN
Thermostats:
The following Amana
Filters:
Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or
CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in
the duct system such as a central return.
10
Great user manuals database on
®
brand Thermostats are suggested for use with the AMH8 Furnace Models:
Thermostat
Mech./Digital
CHT-18-60
Mechanical
CH70TG
Digital
CHSATG
Mechanical
H20TWR
Mechanical
Side Return(s)
Cabinet
Nominal
Flow Area
Width
Filter Size
(in.)
(in.)
All
16 x 25 x 1
FURNACE INPUT
45M
70M
90M
115M
140M
45M
70M
90M
115M
140M
PERMANENT NOMINAL 600 F.M. FACE VELOCITY
DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY
UserManuals.info
THERMOSTATS
Programmable
Yes
No
Yes
Yes
Upflow Filters
Bottom Return
Approx.
Cabinet
Width
2
(in.)
(in
)
400
14
17-1/2
21
24-1/2
MINIMUM FILTER SIZES
FILTER SIZE
2
160 in
2
241 in
2
320 in
2
400 in
2
370 in
2
320 in
2
483 in
2
640 in
2
800 in
2
738 in
Cool
Heat
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Approx.
Nominal
Flow Area
Filter Size
2
(in.)
(in
)
12 x 25 x 1
300
14 x 25 x 1
350
16 x 25 x 1
400
20 x 25 x 1
500
TYPE
permanent
permanent
permanent
permanent
permanent
disposable
disposable
disposable
disposable
disposable

Advertisement