ADC PG-PLUS Technical Practice

Remote line unit
Hide thumbs Also See for PG-PLUS:

Advertisement

Quick Links

S
SCP-PRL771-012-05H
ECTION
PG-P
LUS
T
P
ECHNICAL
TELEPHONE
NETWORK
INTERFACE
R
L
EMOTE
INE
Model
List
CLEI Code
PRL-771
1B
S9MSBB0A~~
RACTICE
CUSTOMER
ACCESS
U
NIT

Advertisement

Table of Contents
loading

Summary of Contents for ADC PG-PLUS

  • Page 1 PG-P ECHNICAL RACTICE TELEPHONE NETWORK INTERFACE CUSTOMER ACCESS EMOTE Model List CLEI Code PRL-771 S9MSBB0A~~ SCP-PRL771-012-05H ECTION...
  • Page 3 Information furnished by ADC is believed to be accurate and reliable. In no event shall ADC be liable for any damages resulting from the loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 4 • Unpack each container and visually inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC. Order replacement equipment, if necessary. •...
  • Page 5: Table Of Contents

    Attach the Frame-Ground Wire ..............8 Attach the POTS Drops ................11 Close the Housing......................14 Fault Isolation ........................14 Product Support _____________________________________________________________________ 15 Technical Support ..........................15 Limited Warranty..........................15 Returns .............................15 FCC Class B Compliance ........................17 Modifications ...........................17 Acronyms ............................18 PG-Plus PRL-771 January 6, 2003...
  • Page 6 SCP-PRL771-012-05H January 6, 2003 PG-Plus PRL-771...
  • Page 7 SCP-PRL771-012-05H IST OF IGURES 1. Typical PG-Plus System..........................1 2. Securing the Customer Access Door......................4 3. Securing a Line Module ..........................5 4. Reference Label...............................6 5. Installing the RT Enclosure ..........................7 6. Opening the Telco Access Door........................8 7. Attaching the Frame-Ground Wire........................9 8.
  • Page 8 SCP-PRL771-012-05H January 6, 2003 PG-Plus PRL-771...
  • Page 9: Prl-771 Overview

    If an RLU is present, the system begins HDSL synchronization acquisition. Relays in the COLU and RLU under control of the PG-Plus PAU provide a path for Subscriber Drop Testing (SDT) and metallic fallback operation. These relays are used to establish a circuit to POTS # 1 during fault conditions and to provide for drop testing of the selected subscriber line from the CO location.
  • Page 10: Specifications

    HDSL 3-terminal station protector, 3/8-inch hex nut POTS Screw Terminals on RJ-11 line interface Dimensions Height 10.25 in. (26.0 cm.) Width 8.5 in. (21.6 cm.) Depth 4.75 in. (12.1 cm.) Weight 4 lbs. (1.81 kg.) January 6, 2003 PG-Plus PRL-771...
  • Page 11: Required Tools And Test Equipment

    RLU by applying + 100 V dc with respect to ground to the HDSL pair. The COLU also initiates a start-up after a momentary short has been applied to the HDSL pair. The COLU responds with start-up voltage three seconds after removal of the short. PG-Plus PRL-771 January 6, 2003...
  • Page 12 ACCESS Customer Access screw Customer-padlock hole Figure 2. Securing the Customer Access Door Subscribers can place a padlock through the customer-padlock hole drilled into the Customer Access door hasp to secure the Customer Access door. January 6, 2003 PG-Plus PRL-771...
  • Page 13 RT, the subscriber can protect his line against unauthorized use by placing a padlock through the latch on the appropriate Line Module door (Figure 3). Figure 3. Securing a Line Module PG-Plus PRL-771 January 6, 2003...
  • Page 14: Reference Label

    RISK OF ELECTRICAL SHOCK, VOLTAGES PUP TO 280 VDC MAY BE PRESENT PON TELECOMMUNICATIONS CIRCUITS. WARNING CONNECT FRAME GROUND TO EARTH GROUND, PFAILURE TO DO SO MAY RESULT IN DAMAGE TO PTHE UNIT AND RISK OF ELECTRICAL SHOCK. Figure 4. Reference Label January 6, 2003 PG-Plus PRL-771...
  • Page 15: Install The Rt Enclosure

    Use the two #10 x 1.5-inch wood screws and flat washers provided in the Mounting Kit to attach the RT enclosure to the side of the customer residence (see Figure 5). For installation on stucco or other suitable surface, use the two ADC provided #10 x 1-inch anchor nuts.
  • Page 16: Attach The Frame-Ground Wire

    Insert the frame-ground wire into the RT enclosure through the hole made in step 1. A 10 AWG copper frame ground wire is recommended. Loosen and remove from the ground-binding post the top nut and three flat washers. January 6, 2003 PG-Plus PRL-771...
  • Page 17 SCP-PRL771-012-05H PRL-771 Overview Loop the frame-ground wire around the ground-binding post. Replace in reverse order and tighten the hardware removed in step 4. Figure 7. Attaching the Frame-Ground Wire PG-Plus PRL-771 January 6, 2003...
  • Page 18 Loosen only the top nut on the Tip and Ring gas tube protection binding posts (see Figure 8). If this unit is to be pole mounted, ADC recommends that the subscriber drop wires be connected directly to the appropriate gas tube protection binding posts.
  • Page 19: Attach The Pots Drops

    Cutting the grommet with a utility knife or something similar is not recommended, because this may cause a large opening in the grommet that would allow insects or other contaminants to enter the enclosure. Lift the appropriate Line Module door (see Figure 9) Figure 9. Inserting the POTS Wires PG-Plus PRL-771 January 6, 2003...
  • Page 20 Insert the POTS wire pair through the cutout on the right side of the Line Module (Figure 10). Connect the Tip conductor to the green terminal lug on the Line Module. Connect the Ring conductor to the red terminal lug on the Line Module Figure 10. Attaching the POTS Wire Pair January 6, 2003 PG-Plus PRL-771...
  • Page 21 PRL-771 Overview URN UP AND ESTING To turn-up and test the Pg-Plus system: Open all the Line Module doors and unplug each RJ-11 jack to ensure there are no off-hook conditions present from the subscriber lines (see Figure 11) Figure 11. Unplugging the RJ-11 Jack Apply a short between the HDSL Tip and Ring conductors for at least for ten seconds.
  • Page 22: Close The Housing

    Verify that the signal loss on the pair is no more than 41 dB at 196 kHz. Replace the RLU. Replace the corresponding COLU. Check for a short placed on the HDSL Tip and Ring conductors, and remove if necessary. Check for HDSL cable fault, and replace if necessary. January 6, 2003 PG-Plus PRL-771...
  • Page 23: Product Support

    ADC’s Return Material Authorization (RMA) Department. Call or write ADC’s RMA Department to ask for an RMA number and any additional instructions. Use the telephone number, fax number or email address listed below: •...
  • Page 24 If there is another reason for returning the equipment, please let us know so we can determine how best to help you. Pack the equipment in a shipping carton. Write ADC’s address and the RMA Number you received from the RMA Department clearly on the outside of the carton and return to: ADC DSL Systems, Inc.
  • Page 25: Fcc Classb Compliance

    The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by ADC voids the user's warranty. All wiring external to the product(s) should follow the provisions of the current edition of the National Electrical Code.
  • Page 26: Acronyms

    High-bit-rate Digital Subscriber Line Light-Emitting Diode Mechanized Loop Test PG-Plus Alarm Unit POTS Plain Old Telephone Service PG-Plus Remote Line unit Remote Line Unit (circuitry only) Return Materials Authorization Remote Terminal (enclosure and RLU inclusive) Subscriber Drop Test January 6, 2003...
  • Page 28 World Headquarters: ADC Telecommunications, Inc. 12501 Whitewater Drive Minnetonka, Minnesota USA 55343 For Technical Assistance: 800.366.3891 ´,Sp¶4@¨ 1251804...