Operation Environment; Refrigerant - Westinghouse WPAC8000 User Manual

Portable room air conditioner
Table of Contents

Advertisement

should be serviced by an authorized service center in
compliance with local laws and regulations.
• Children should be supervised to ensure that they do
not play with the appliance.

OPERATION ENVIRONMENT

• During operation, close doors and windows to improve
cooling. Place the air conditioner on a smooth, flat
surface to minimize noise and vibration.
• This air conditioner is equipped with casters, which will
slide easily on a smooth, flat surface.
• Do not operate the air conditioner on an incline or in
any position other than upright. If the unit tips over,
disconnect power immediately and contact dealer.
• Do not operate in direct sunshine.

REFRIGERANT

This unit uses a non-explosive flammable refrigerant
gas, R32, which can be ignited by fire.
The refrigerant used in this unit is the fluoride R32, which
is specially cleaned. The refrigerant is considered mildly
flammable and has no odor.
Compared to common refrigerants, R32 is a nonpolluting
refrigerant with no harm to the ozonosphere. The influence
upon the greenhouse effect is also lower. R32 has very
good thermodynamic features and high energy efficiency.
The units therefore need less filling.
• Appliance filled with flammable gas R32
• Appliance shall be installed,operated and stored in a
room with a floor area larger than 40 square feet (4
square meters).
• The appliance shall be stored in a room without
continuously operating ignition sources (for example:
open flames, an operating gas appliance, or an
operating electric heater.)
• The appliance shall be stored in a well-ventilated
area where the room size corresponds to the room
area as specified for operation.
• The appliance shall be stored so as to prevent
mechanical damage from occurring.
• Ducts connected to an appliance shall not contain an
ignition source.
• Keep any required ventilation openings clear of
obstruction.
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• Do not use means to accelerate the defrosting
process or to clean,other than those recommended
by the manufacturer.
• Servicing shall be performed only as recommended
by the manufacturer.
• Should repair be necessary, contact your nearest
authorized Service Center. Any repairs carried out by
unqualified personnel may be dangerous.
• Compliance with national gas regulations shall be
observed.
• Read service manual.
Westinghouse Outdoor Power Equipment | 5