Section 2. Unit Location Considerations

2.1 Unit Dimensions and Weight
Table 2.1
Unit Dimensions and Weight
Models
H x D x W (in)
4TTR6024N
4TTR6036N
4TTR6048N
4TTR6060N
4TTR6018J
4TTR6024J
4TTR6030J
4TTR6035J
4TTR6036J
4TTR6041J
4TTR6042J
4TTR6048J
4TTR6049J
4TTR6060J
4TTR6060K
4TTR6061C
* Weight values are estimated.
When mounting the outdoor unit on a roof, be sure the roof will support the unit's weight.
Properly selected isolation is recommended to alleviate sound or vibration transmission to the building structure.
2.2 Refrigerant Piping Limits
1. The maximum TOTAL length of refrigerant
lines from outdoor to indoor unit should
NOT exceed 150 feet (including lift).
2. The maximum vertical change should not
exceed 50 feet.
3. Service valve connection diameters are
shown in Table 5.1.
Note: For other line lengths, Refer to Refriger-
ant Piping Application Guide, SS-APG006-EN
or Refrigerant Piping Software Program, 32-
3312-03 (or latest revision).
18-AC98D1-7D-EN
Weight* (lb)
41 x 34 x 37
244
45 x 34 x 37
250
45 x 34 x 37
254
45 x 34 x 37
275
29 x 30 x 33
161
29 x 30 x 33
162
37 x 30 x 33
184
33 x 30 x 33
156
37 x 34 x 37
212
37 x 34 x 37
212
45 x 34 x 37
252
45 x 34 x 37
256
45 x 34 x 37
272
45 x 34 x 37
277
45 x 34 x 37
252
45 x 34 x 37
280
W
H
D
Standard
Line Set
150' Max
TOTAL Line Length
3