Advertisement

Quick Links

SDM BATTERY SERIES
USER MANUAL
70-2.000 Nm
WWW.RADIALTORQUE.EU
NL
ENG
DU
FR
TURK
POL

Advertisement

Table of Contents
loading

Summary of Contents for Radial Engineering SDM BATTERY Series

  • Page 1 SDM BATTERY SERIES 70-2.000 Nm TURK USER MANUAL WWW.RADIALTORQUE.EU...
  • Page 2 User manual SDM Battery Series Table of contents 1. Before taking into use 2. Charging the batt ery 2.1 Moun� ng the ba� ery 2.3 Removing the ba� ery 2.4 Ba� ery charger light Indica� on 3. Safety 3.1 Electrical Safety 3.2 Ba�...
  • Page 3: General Instruc� Ons

    NOTE: Do not operate the tool before reading these instructions. If breakdown, malfunction or damage occurs, do not attempt to repair, please contact Radial Torque Tools B.V. immediately. SDM Battery Series torque wrenches are reversible, non-impacting, torque controlled tightening tools and must always be operated with the following: •...
  • Page 4 User manual SDM Battery Series 3. Setting Torque and / or Angle Step 1: Slide in battery Step 2: Go the password Step 3. Use password "FFFF" screen F F F F Step 4. Confirm password Step 5: Go to strategy Step 6: Choose between with "ENTER...
  • Page 5 Blue - The tool has an active fault condition. 5. Screen explained (Advanched Series only) 5.1. Programming keys The image below shows the screen of SDM Battery Series screen module with descriptions of the programming keys. EXIT UP / DOWN / LEFT / RIGHT ENTER / EXIT Version 1.0 - August 2022...
  • Page 6 User manual SDM Battery Series 5.2. Icon list Sets angle Angle Sets torque Torque To tighten the bolt Clock wise To loosen the bolt Anti clockwise Indicates unit of the torque displayed Unit of torque Sets the torque and angle...
  • Page 7 User manual SDM Battery Series 5.3. Main screen Pressing “ENTER” key after switching on the screen will show this image. The PRIMARY SECTION - shows latest peak torque (for a torque strategy) or the latest peak angle (for an angle strategy), with units.
  • Page 8 The password screen shows whether the tool is locked or unlocked. If the tool is locked the parameters of the SDM Battery Series cannot be edited. Password can be entered by pressing the “ENTER“ key and using the “UP” or “DOWN” key.
  • Page 9 User manual SDM Battery Series 5.7. Set torque and enable/disable RF After screen is unlocked with a valid password, Pressing “RIGHT” key will allow you to set torque and / or angle. See section 3. Setting Torque and / or Angle for more information.
  • Page 10 User manual SDM Battery Series 5.10. Shiftdown point config This screen indicates “Torque Threshold for shiftdown point”. This can be changed by entering edit mode and updating using “UP” or “DOWN” key. 5.11. Free Speed The below screen indicates free speed of the SDM Battery tool.
  • Page 11 User manual SDM Battery Series 5.14. Angle The PRIMARY SECTION - Target Angle. The torque at which reading of the angle will be The SECONDARY LEFT - Angle low. started. The value can be edited by entering edit mode and using “UP” and “DOWN” key.
  • Page 12 User manual SDM Battery Series 5.16. Direction of rotation Image shows direction of rotation in which the SDM Battery rotates. Indicates counter clock wise rotation and clock wise rotation. This can be changed by entering edit mode key and updating using “RIGHT” or “LEFT” key.
  • Page 13 User manual SDM Battery Series 5.19. Warning screen This is the next screen obtained after pressing “UP” key when SDM Battery tool displays the Password screen. 5.20. Shunt Calibration, RF Signal Strength and Battery level This is the next screen obtained after pressing “UP” key when the tool displays password screen.
  • Page 14 User manual SDM Battery Series 6. Battery Before initial use, check that the voltage and frequency stated on the charger’s rating plate match the figures for your own electrical supply. Unplug charger immediately if the cable or charger is damaged. Unplug immediately if any sign of smoke or flames.
  • Page 15: Battery Charger

    User manual SDM Battery Series 7. Batt ery charger Before initial use, check that the voltage and frequency stated on the rating plate match your own electrical supply and check that the ventilation slits are clear. Minimum clearance from other objects is 5 centimeters.
  • Page 16: Parts And Maintenance

    User manual SDM Battery Series NOTE: Improper reaction will void warranty and can cause premature tool failure. 8.3. Reaction arm foot Ensure the foot of the reaction arm aligns with the length of the nut as seen in Figure 8.3A. The length of the foot cannot be shorter or longer than the nut as seen in Figure 8.3B and Figure 8.3C.
  • Page 17: Product Specific Safety Rules

    User manual SDM Battery Series 11. Safety Radial tools are developed for tightening and loosening threaded fasteners using very high forces. For your safety and that of others, warning labels and attention labels are prominently attached to the torque wrench and its accessories.
  • Page 18 User manual SDM Battery Series 13. Tool Fault codes Tool Disabled (by external control) F-01 Rapid Trigger pull – trigger was pulled before configuration delay was complete F-02 USB enumeration fault 1-FF Motor controller communication timeout A-10 A display software version update was detected...
  • Page 19 User manual SDM Battery Series Current display unit value is unsupported C-14 Torque Threshold exceeds target (with torque target) or max torque (with Target Angle) C-15 Invalid Configuration selection C-55 Battery Fault E-00 Invalid Hall State E-01 I2T Fault E-02...
  • Page 20 User manual SDM Battery Series The configuration ID in the Motor controller’s EOR did not match the currently selected E-81 configuration PM Alarm Time Fault for corresponding Alarm ID normally configured by the user 2-<Alarm ID> PM Alarm Cycle Fault for corresponding Alarm ID normally configured by the user 3 -<Alarm ID>...
  • Page 21: Warranty

    User manual SDM Battery Series including an overheated tool. Uncontrolled tool operation may cause various hazards including heat, smoke or fire. • Do not block the housing cooling air holes as this may cause overheating of the tool. Use of the tool in this condition may result in heat, smoke or fire with injury or property damage.
  • Page 22 User manual SDM Battery Series Notes Version 1.0 - August 2022...
  • Page 23 User manual SDM Battery Series Notes Version 1.0 - August 2022...
  • Page 24 THE EXCLUSIVE MASTER DISTRIBUTOR FOR RAD TORQUE SYSTEMS IN EAST- AND WESTERN EUROPE (EXCLUDING THE UK), NORTH AFRICA AND CENTRAL ASIA: RADIAL TORQUE TOOLS B.V. ZUIDERGRACHT 19 3763 LS SOEST THE NETHERLANDS Phone: +31(0)35 588 24 50 E-MAIL: SALES@RADIALTORQUE.EU www.radialtorque.eu...

Table of Contents