4-10. FOCUS BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
4-10-1. Focus Brush Position Adjustment (Search Focus Adjustment Point)
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1) Remove the outer cover from the lens body.
Note:
Remove the outer cover little by little, inserting the Philips screw driver in the slit portion of outer cover.
Outer Cover
Slit Portion
2) Connected to equipment with checking lens. (Refer to Section 4-1-3.)
3) Start up of "ActuatorChecker.exe".
[Set up]
4) Click
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Adjusting Method
1) Set the focus position to infinity position.
2) Loosen two screws fixing the brush base plate.
Screws
Fig.4-10-2
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
Outer Cover Affixing Block
Fig.4-10-1
4-38