Introduction
The PD4-E-M is a brushless motor with integrated controller in protection class
IP65. The integrated absolute encoder makes immediate operation possible in
closed loop mode without homing.
This instruction describes the installation and commissioning of the motor. You
can find the detailed documentation for the product and motor data sheets on
us.nanotec.com
. The short instructions do not replace the technical manual of
the motor.
Copyright
©
2013 – 2022 Nanotec Electronic GmbH & Co. KG. All rights reserved.
Intended use
The PD4-E-M motor with integrated controller is used as a component of drive
systems in a range of industrial applications.
Use the product as intended within the limits defined in the technical data (in
particular, see ) and the approved
.
Environmental conditions
Under no circumstances may this Nanotec product be integrated as a safety
component in a product or system. All products containing a component
manufactured by Nanotec must, upon delivery to the end user, be provided
with corresponding warning notices including instructions for safe use and safe
operation. All warning notices provided by Nanotec must be passed on directly
to the end user.
Warranty and disclaimer
Nanotec is not liable for damage and malfunction from installation errors, failure
to observe this document, or improper repair. Responsible for the selection,
operation, use of our products is the plant engineer, operator and user. Nanotec
accepts no liability for product integration in the end system. The general terms
and conditions at www.nanotec.com apply (customers of Nanotec Electronic
USA please see
us.nanotec.com
). Note: Product modification / alteration is
illicit.
Target group and qualification
The product and this documentation are directed towards technically trained
specialists staff such as: development engineers, plant engineers, installers/
service personnel, and application engineers.
Only specialists may install, program and commission the product. Specialist
staff are persons who
have appropriate training and experience in working with motors and their
control,
are familiar with and understand the content of this technical manual,
know the applicable regulations.
EU directives for product safety
The following EU directives were observed:
RoHS directive (2011/65/EU, 2015/863/EU)
EMC directive (2014/30/EU)
Other applicable regulations
In addition to this technical manual, the following regulations are to be observed:
Accident-prevention regulations
Local regulations on occupational safety
Safety and warning notices
NOTICE
Damage to the controller!
Changing the wiring during operation may damage the
controller.
► Only change the wiring in a de-energized state. After
switching off, wait until the capacitors have discharged.
NOTICE
Damage to the controller due to excitation voltage of the
motor!
Voltage peaks during operation may damage the controller.
► Install suitable circuits (e. g., charging capacitor) that reduce
voltage peaks.
NOTICE
Damage to the electronics through improper handling of
ESD-sensitive components!
The device contains components that are sensitive to
electrostatic discharge. Improper handling can damage the
device.
► Observe the basic principles of ESD protection when
handling the device.
NOTICE
Damage to the electronics if the supply voltage is
connected with reversed polarity!
Polarity reversal results in a short-circuit between supply
voltage and GND (earth) via the power diode.
► Install a line protection device (fuse) in the supply line.
Technical details and pin assignment
Environmental conditions
Environmental condition
Value
Protection class
IP65 (except for
shaft output)
Ambient temperature (operation)
-10 ... +40°C
Air humidity (non-condensing)
0 ... 85%
Max. Altitude of site above sea level (without drop in
1500 m
performance)
Ambient temperature (storage)
-25 ... +85°C
Electrical properties and technical data
Technical data – motor
PD4-E
PD4-EB
Type
Stepper motor
BLDC
Operating voltage
12 - 48 V DC ±5%
12 - 48 V DC ±5%
Rated current rms
4.2 A
6 A
Peak current rms for 5 s
5.5 A
18 A
Technical data
Operating modes
Profile Position Mode, Profile Velocity Mode,
Profile Torque Mode, Velocity Mode, Homing
Mode, Interpolated Position Mode, Cyclic Sync
Position Mode, Cyclic Sync Velocity Mode, Cyclic
Synchronous Torque Mode,
Set value setting /
EtherCAT, analog input, NanoJ program
programming
Inputs
6 digital inputs (+5 V/+24 V DC), individually
switchable by means of software, factory settings: 5 V
1 analog input 0–10 V or 0–20 mA (switchable by
means of software)
Outputs
2 outputs, Open Drain, max. 100 mA
Integrated encoder
Magnetic multiturn absolute encoder, single-turn
resolution: 17 bit (131072 per revolution), multiturn
15
resolution: 16-bit (+/-2
revolutions)
Protection circuit
Overvoltage and undervoltage protection
Overtemperature protection (> 68° Celsius on rear
cover)
Polarity reversal protection: In the event of a polarity
reversal, a short-circuit will occur between supply
voltage and GND over a power diode; a line protection
device (fuse) is therefore necessary in the supply
line. The values of the fuse are dependent on the
application and must be dimensioned
greater than the maximum current consumption
of the controller,
less than the maximum current of the voltage
supply.
If the fuse value is very close to the maximum current
consumption of the controller, a medium / slow
tripping characteristics should be used.
Dimensioned drawings
All dimensions are in millimeters.
Dimension
Value
L
PD4-E591L42-M-65: 126.5±1
PD4-EB59CD-M-65: 146.5±1
W
PD4-E591L42-M-65: 57
PD4-EB59CD-M-65: 57
H1
PD4-E591L42-M-65: 56.4±0.5
PD4-EB59CD-M-65: 56.6±0.5
H2
PD4-E591L42-M-65: 89.7
PD4-EB59CD-M-65: 89.7
D1
+0
PD4-E591L42-M-65: 6.35
-0.013
+0
PD4-EB59CD-M-65: 8
-0.013
D2
PD4-E591L42-M-65: 38.1±0.025
+0
PD4-EB59CD-M-65: 38.1
-0.05
D3
PD4-E591L42-M-65: 5
PD4-EB59CD-M-65: 5.2±0.25
Overtemperature protection
Above a temperature of approx. 75°C on the power board (corresponds to 65–
72°C outside on the back cover), the power part of the controller switches off
and the error bit is set After cooling down and confirming the error , the controller
again functions normally.
LED signaling
Power LED
The power LED indicates the current status.
Normal operation
In normal operation, the green power LED L1 flashes briefly once per second.
Case of an error
If an error has occurred, the LED turns red and signals an error number.
The following table shows the meaning of the error numbers.
Flash
Error
rate
1
General
2
Voltage
3
Temperature
4
Overcurrent
5
Controller
6
Watchdog-Reset
NOTICE
For each error that occurs, a more precise error code is stored in
object 1003
.
h
Pin assignment
Connector Function
Pin assignment / description
X1
EtherCAT IN
1.
TD+
X2
EtherCAT OUT
2.
RD+
3.
TD-
4.
RD-
X3
Voltage supply
1.
+Ub
2.
+Ub
3.
GND
12 - 48 V DC ±5%
4.
GND
5.
n.c
X4
Inputs/outputs
1.
GND
and external logic
2.
Digital input 1
: 5 V / 24 V, switchable
supply
with object
3240
, max. 1 MHz
h
3.
Digital input 2
: 5 V / 24 V, switchable
with object
3240
, max. 1 MHz
h
Switching
4.
Digital input 3
: 5 V / 24 V, switchable
thresholds for
with object
3240
, max. 1 MHz
h
digital
inputs 1 - 6
:
5.
Digital input 4
: 5 V / 24 V, switchable
5 V (factory
with object
3240
, max. 1 MHz
h
setting): On:
6.
Digital input 5
: 5 V / 24 V, switchable
>4.09 V; Off: <0.95
with object
3240
, max. 1 MHz
 V
h
7.
Digital input 6
: 5 V / 24 V, switchable
24 V: On: >14.74
with object
, max. 1 MHz
3240
h
 V; Off: <3.78 V
8.
: 10 Bit, 0-10 V or
Analog input
0-20 mA, switchable with object
9.
: Open drain, max 24
Digital output 1
 V/100 mA
10.
Digital output 2
: Open drain, max 24
 V/100 mA
11.
5V output
: +5 VDC, max. 100 mA
12.
+UB Logic
: 4 V DC/approx. 39 mA
3221
h

Advertisement

loading

Summary of Contents for NANOTEC PD4-E-MA

  • Page 1 Ambient temperature (storage) -25 … +85°C EtherCAT IN operation, use of our products is the plant engineer, operator and user. Nanotec accepts no liability for product integration in the end system. The general terms EtherCAT OUT and conditions at www.nanotec.com apply (customers of Nanotec Electronic...