Advertisement

Quick Links

USER'S MANUAL
MULTI SYSTEM
SYMPHONY
MS-H09AISW, MS-H12AISW

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair MS-H09AISW

  • Page 1 USER'S MANUAL MULTI SYSTEM SYMPHONY MS-H09AISW, MS-H12AISW...
  • Page 2 “Original instructions”  ...
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts Name......................2 Screen Operation Guide Buttons on remote controller.................. 3 Introduction for buttons on remote controller............4 Replacement of batteries in remote controller............7 Emergency operation ................... 8 Maintenance Clean and Maintenance..................8 Malfunction Malfunction analysis ....................11 Installation Notice Installation dimension diagram ................15 Tools for installation .....................16...
  • Page 4: Precautions

    Precautions Warning ● Do not connect air conditioner to multi-purpose socket.Otherwise, it may ● Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock. ● Do not spray water on indoor unit. It may cause electric shock or malfunction. ●...
  • Page 5: Parts Name

    Parts Name Indoor Unit air inlet panel air outlet horizontal louver temp. indicator cooling indicator heating indicator drying indicator defrosting indicator power indicator remote controller (Display content or position may be different from above graphics, please refer to actual products) Notice: Actual product may be different from above graphics, please refer to actual products.
  • Page 6: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button +/- button MODE button Note: This remote controller  button is universal and can be used  SWING button for multi‐functional air  I FEEL button conditioning. If the button on  the remote controller with  button the function which the air  SLEEP button conditioner doesn’t have is  pressed, the unit remains in  TEMP button its original operating mode. QUIET button ClOCK button T-ON T-OFF button TURBO button X-FAN button LIGHT button Introduction for icons on display screen I feel...
  • Page 7: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller ON/OFF Press this button to turn on the unit. Press this button again to turn off the unit. Press this button to decrease set temperature. Holding it down above 2 seconds rapidly decreases set temperature. In AUTO mode, set temperature is not adjustable. Press this button to increase set temperature.
  • Page 8 Introduction for buttons on remote controller Press this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the first time to start scavenging function; LCD displays“ ”. Press the button for the second time to start healthy and scavenging functions simultaneously;...
  • Page 9 Introduction for buttons on remote controller TEMP: Press this button, you can see indoor set temperature, indoor ambient temperature on indoor unit’s display. The setting on remote controller is selected circularly as below: no display When selecting " " with remote controller or no display, temperature indicator on indoor unit displays set temperature;...
  • Page 10: Replacement Of Batteries In Remote Controller

    Introduction for buttons on remote controller X-FAN: Pressing X-FAN button in COOL or DRY mode, the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted.
  • Page 11: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 12 Clean and Maintenance Open panel Pull out the panel to a certain ● Use dust catcher or water to the water (below 45℃ ) to clean it, and then put it in a shady and cool place to dry. panel cover tightly. Note: operation environment, clean frequency can be increased.
  • Page 13 Clean and Maintenance Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 14: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity,stable the plug after about 3min, and voltage)?
  • Page 15 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Air switch trips off or fuse is ● Ask professional to replace burnt out? air switch or fuse. Air condit- ●...
  • Page 16 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted etc. ● Whether there’s interference, ● Disconnect power, put back Air conditioner such as thunder, wireless power, and then turn on the operates abno devices, etc.
  • Page 17 Malfunction analysis Error Code ● When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Above indicator diagram is only Error code for reference. Please refer to actual product for the actual Indoor indicator and position. display Below listed error codes are only part error codes.
  • Page 18: Installation Dimension Diagram

    Installation dimension diagram...
  • Page 19: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 20: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 21: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 22 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when opening the hole. ● The plastic expansion particles are Φ55 5-10 not provided and should be bought locally. Step four: outlet pipe 1.
  • Page 23 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 40~55 pipe Φ 16 60~65 torque wrench Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 24 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color;...
  • Page 25 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 26: Check After Installation

    Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage It may cause insufficient cooling test? (heating) capacity.
  • Page 27 Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity...
  • Page 28 Configuration of connection pipe Additional refrigerant charging amount for R410A Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16 Φ25.4 or Φ31.8 Φ19...
  • Page 29  ...
  • Page 30 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd., 1-4 Argyll Street, London W1F 7LD, UK Supplier and technical support: Nepa, spol.s.r.o.

This manual is also suitable for:

Ms-h12aisw

Table of Contents