Onkyo TX-RZ720 Service Manual page 20

Hide thumbs Also See for TX-RZ720:
Table of Contents

Advertisement

1
How to Check Idling Current
a. Idling Pre-check
Channel
D
Terminals
*Connect 1/4W 100 ohms resisters in each probe of multi mater .
*Make sure from 1mV to 21mV, When it is not this range, you have to make sure again repair.
b. Aging
The AVR is turned on about 6 minutes for aging.
C
c. Idling After-check
*Equip series 1/4W 100-ohm resisters near the terminal respectively in each pole of the jig used for the above mentioned terminals.
*If the measured value are under 1 mV or over 21 mV, turn off the power of the AVR and rework the AVR.
*Connect 1/4W 100 ohms resisters in each probe of multi mater .
*Make sure from 1mV to 21mV, When it is not this range, you have to make sure again repair.
B
A
1
2
3
FL,FR,C,SL,SR,SBL,SBR
P6021,P6022,P6023,P6025,P6026,P6027,P6028
2
3
4
5
Check Idling Current
4
5
6
D
C
B
A
TX-NR575/676/676E/777
HT-R997
TX-RZ620/720/820
DRX-2.1/3.1
6

Advertisement

Table of Contents
loading

Table of Contents