Page 1
ORDER NO.PHAMOS0601003A1 Microwave Oven NN-SN776S / NN-SN756S / NN-SN756B / NN-SN756BT / NN- SA746M APH(USA) CPH(CANADA) Please file and use this specified manual together with the service manual for Model NN-T695 (ORDER NO. PHAMOS0501001C1). SPECIFICATIONS...
Page 2
2006 Panasonic Home Appliances Microwave Oven (Shanghai) Co., Ltd. / All rights reserved. Unauthorized copying and distribution is a violation of law.
Page 8
2.1. Adjustment of primary latch switch, secondary latch switch and short switch. 1. Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL. NOTE: No specific individual adjustments during installation of the Primary latch switch, Secondary latch switch or Short switch to the door hook are required.
2.2. Measurement of microwave output The output power of the magnetron can be determined by performing IEC standard test procedures. However,due to the complexity of IEC test procedures, it is recommended to test the magnetron using the simple method outlined below. Necessary Equipment: *1 liter beaker *Glass thermometer / *Wrist watch or stopwatch NOTE:...
RATED OUTPUT TEMPERATURE RISE 1200W Min. 18.5°F(10.3°C) 1300W Min. 19.8°F(11.1°C) 3. PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE NOTE: The U.S. Government standard is 5 mW/cm while in the customer’s home. 2mW/cm stated here is our own voluntary standard. (1mW/cm for Canada) 3.1.
supplied with the probe. 4. Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured. 3.2.1. Measurement with the outer panel removed. Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted.
TROUBLESHOOTING Purpose: Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below. Procedure: Follow the matrix table below to identify the problem source. Note: Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure.
Page 20
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F3018-1200 DOOR KEY A F301A8E00SAP DOOR A (U) SN776S APH,SN756S APH F301A8E00SCP DOOR A (U) SN776S CPH F30016J00BAP DOOR A SN756B APH,SN756BT APH F30016J00SAP DOOR A SA746M APH F302K4W00AP DOOR E (U) F30215G10XN DOOR KEY SPRING F30854W00AP...