Installation – Built In Gravity Drain
• Plan the installation for machine removal
– Coil of water supply tubing
– Arrange the drain tubing so it does not kink when the
machine is pushed into place
• Recommended drain tube size is 5/8" ID, 7/8" OD
plastic hose
• Will connect to elbow on machine drain
• Use 2-3 foot section of 5/8" OD copper to guide
drain tube into cabinet while pushing unit back
• Reach back to insert elbow into hose, secure with
clamp