PIF ADJUSTMENT
NO. Adjustment part
Adjusting procedure and conditions
1
Tuner IFT
1. Get the tuner ready to receive the E-9 CH
(PRESET)
signal, but with no signal input.
Adjust the PLL data.
2. Connect the sweep generator's output cable
to the tuner antenna. (RF SWEEP)
3. Adjust the sweep generator's to 80dBuV.
4. Connect the response lead (use LOW IMPED-
ANCE probe with wave detector; see Fig.1) to
the tuner's IF output terminal. (This terminal
must have the probe alone connected).
5. Set the RF AGC to 0 - 6 V with no saturation
with the waveform.
6. Adjust the tuner IF coil to obtain the waveform
as shown in Fig. 2.
Note: Be sure to keep the tuner cover in
position during this adjustment.
2
RF-AGC
1. Receive "PAL COLOUR BAR" signal.
» Signal Strength: 57 ±1 dBµV (75 ohm open)
TAKE OVER
POINT
ADJUSTMENT
2. Connect the oscilloscope to TP201 (Tuner's
(I
2
C BUS
AGC Terminal) as shown in Fig. 3.
CONTROL)
Oscilloscope
+
0.1V
Bias box
+
» Bias box: About 4.5 V
Fig. 3
3. Call "AG" mode in service mode. Adjust the
"AG" bus data to obtain the Tuner output pin
drop 0.1 V below maximum voltage.
4. Change the antenna input signal to
63~67dBµV, and make sure there is no noise.
5. Turn up the input signal to 90~95 dBµV to be
sure that there is no cross modulation beat.
Waveform and others
1n60
1000p
10k
Oscilloscope
100k
75ohm
Fig. 1
E-9 CH
P
C
-1.5+/-0.8dB
Fig. 2
Note:
For the 50 ohm signal strength
gauge, when not using 50/75
impedance adapter, signal
strength is 52 ±1 dBµV(75 ohm
open), instead of 57 ±1 dBµV
(75 ohm open).
TP201
Precaution:
The loss of using impedance
adapter
TV Set
7-1
NO. Adjustment part
Adjusting procedure and conditions
1
PURITY ADJ.
1. Receive the GREEN-ONLY signal. Adjust the
beam current to about 700 µA.
2. Degauss the CRT enough with the degausing
coil.
Note: Follow the Job Instruction Sheet to ad-
IF OUT
3. Maintain the purity magnet at the zero
magnetic field and keep the static convergence
roughly adjusted.
4. Observe the points a, b as shown in Fig. 4-1
through the microscope. Adjust the landing to
the rank A requirements.
5. Orient the raster rotation to 0 eastward.
6. Tighten up the deflection coil screws.
» Tightening torque: 108 ± 20 N (11 ±2 kgf)
7. Make sure the CRT corners landing meet the
A rank requirements. If not, stick the magnet
sheet to correct it.
Note: This adjustment must be done after
Note: Set the service mode by JA122 &
* For the following colours press R/C RGB key
to change.
Green-only
PURITY ADJUSTMENT
Waveform and others
a
just the magnetic field.
Vertical Bv
: -0.050 mT
(-0.50 gauss)
Horizontal Bh : +0.020 mT
(0.20 gauss)
warming up the unit for 30 minutes
(on the right of the CRT)
or longer with a beam current over
700 µA.
JA124 (short) then press factory proc-
ess R/C RGB key to change to RGB
mono colour mode.
Red-only
Blue-only
(on the left of the CRT)
Signal-colour
screen cleared
* Press R/C RGB key for 1 second
in NORMAL MODE, the colour
will change to RGB mono colour
mode.
The TEXT Key "R. G. Cy" Key can
be directly use to change to other
colours screen.
7-2
b
Fig. 4-1
A
B
A = B
Fig. 4-2
Rank "A"
A
B
A = B
Fig. 4-3
Rank "A"

Advertisement