Figure 5: Remove the sensor cover
4.
If using the reed switch, use the two remaining screws to
mount the magnet so that its arrow is aligned with the
arrow on the sensor case (see Figure 6 below).
Figure 6: Sensor base mounting holes and magnet alignment
Adjusting the shock sensor
DIP Switches
The following describes the DIP switch functions:
DIP Switches 1 and 2—adjust the Pulse Count.
DIP Switches 3 and 4—adjust the sensitivity setting of
Gross Attack detection.
DIP Switch 5—enable/disable reed switch.
DIP Switch 6—not used.
Note: In order for the LED to indicate shock detection while
adjusting the sensitivity, be sure the reed switch is disabled
(DIP switch 5 OFF) or that the magnet is lined up with the reed
switch if DIP switch 5 is ON.
Gross Attack Adjustment
1.
To adjust the sensor for Gross Attack, set DIP switches 1
and 2 to the ON position. This disables the Pulse Count so
that the unit can only be activated by a Gross Attack.
2.
Apply high level shocks to the mounting structure, using
the LED as a guide to when the alarm trips (LED on for 4
seconds).
The LED will blink for 1 second every time the sensor
detects a pulse. A shock that is severe enough to cause
International Shock Sensor Installation Instructions
an alarm will cause the LED to light for approximately 4
seconds.
3.
Use switches 3 and 4 to adjust the Gross Attack sensitivity
of the sensor (see Table 1 below)
4.
Repeat step 2 each time you make a sensitivity change.
Table 1: Gross attack sensitivity settings
DIP switch 3
DIP switch 4
Off
Off
On
Off
Off
On
On
On
Pulse Count Adjustment
Note: Pulse Count signals are counted at 1-second intervals
and stored in a 30-second digital memory. These small signals
can detect an intruder gently prying open a window or door
frame.
1.
Set the sensor to the desired Pulse Count (see Table 2
below).
2.
To test the pulse count setting, generate small shocks on
the mounting structure. Each time a shock is detected, a
pulse is registered in memory and the LED will blink for
one second. If the programmed pulse count is reached
within the most recent 30 seconds, the alarm will trip and
the LED will light for approximately 4 seconds. If the alarm
trips for any reason, the stored pulses are cancelled.
3.
Use switches 1 and 2 to adjust the Pulse Count.
4.
Repeat step 2 each time you make a sensitivity change.
Table 2: Pulse count adjustment
DIP switch 1
DIP switch 2
Off
Off
On
Off
Off
On
On
On
System programming
This section describes the basic steps for adding the sensor to
panel memory. Refer to the specific panel installation
instructions for complete programming details.
1.
Enable the reed switch by setting DIP switch 5 to ON. The
reed switch must also be open (no magnet near).
Sensitivity
1 (maximum)
2
3
4 (minimum)
Pulse count
4
6
8
Disabled