Haier AD71S2SM7FA Operation Manual And Installation Manual

Haier AD71S2SM7FA Operation Manual And Installation Manual

Duct type air conditioner

Advertisement

Quick Links

No.0150550063
Keep this operation manual for future reference.
AD71S2SM7FA
AD100S2SM7FA
AD125S2SM7FA
AD140S2SM7FA
Accessory
Move and scrap the air conditioning ........ 21
6
7
8
9
10
13
14
15
16

Advertisement

Table of Contents
loading

Summary of Contents for Haier AD71S2SM7FA

  • Page 1 AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA Accessory AD140S2SM7FA Move and scrap the air conditioning ..21 No.0150550063 Keep this operation manual for future reference.
  • Page 3: Disposal Requirements

    Haier Industrial Park, No.1 Haier road, Qingdao,P.R.China EUROPEAN REGULATIONS IMPORTANT INFORMATION REGA- CONFORMITY FOR THE MODELS RDING THE REFRIGERANT USED Contains fluorinated greenhouse gases covered by the Kyoto Protocol DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste.Do not try to dismantle the...
  • Page 4 o not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. he appliance must be stored in a room without continuously operating ignition sources(for examples: open flames, an operating gas appliance or an operating electric heater). o not pierce or burn.
  • Page 5 Cautions Disposal of the old air conditioner Disposal of the packaging of your new air conditioner Safety Instructions and Warnings...
  • Page 6: Safety Precautions

    Safety Precautions CAUTIONS FOR INSTALLATION CAUTIONS FOR TRANSFER OR REPAIR WARNING...
  • Page 7 Safety Precautions CAUTIONS FOR OPERATION WARNING CAUTION...
  • Page 8 3mm. 8. The indoor unit installation height is at least 2.5m. 9. A leakage breaker must be installed. 10. For AD71S2SM7FA/AD100S2SM7FA /AD125S2SM7FA/AD140S2SM7FA ,we can get the 10 different ESP through adjust wired controller YR-E17A, please refer below: static presssure grade...
  • Page 9: Indoor Unit Pcb

    Installation Manual For Wire Controller 5. Wiring connections of wire controller: There are three methods to connection wire controller and the indoor units: A.One wired controller can control max. up to 16 sets of indoor units, and 3 pieces of polar wire must connect the wire controller and the master unit (the indoor unit connected with wire controller directly), the others connect with the master unit through 2 pieces of polar wire B.
  • Page 10: Heating Mode

    Heating Mode "HOT KEEP" function Warming operation...
  • Page 11: Care And Maintenance

    Care and Maintenance Points to observe CAUTION Cleaning the air filter CAUTION Care and Cleaning of the unit Post-Season Care Pre-Season Care...
  • Page 12: Troubleshooting

    Troubleshooting Unit fails to start Cooling or heating is not sufficient Cooling is not sufficient...
  • Page 13 Troubleshooting The followings are not malfunction...
  • Page 14: Indoor Unit Trouble Shooting

    Troubleshooting INDOOR UNIT TROUBLE SHOOTING AD71S2SM7FA/AD100S2SM7FA/AD125S2SM7FA/AD140S2SM7FA LED flash times Wired Contents of Possible reasons of indoor PCB controller Malfunction display LED4 LED3 Sensor disconected or brok- Malfunction of indoor en,or at wrong position,or unit ambient temper- short circuit ature sensor...
  • Page 15 Accessory Accessory supplied with the indoor unit for AD71/100/125/140 series.  Name Quantity Descriptions Shape 3/8″ Brass nut (liquid side) For tightening the 3/4″Brass nut(gas Connecting pipe side) for AD140S2SM7FA 5/8″ Brass nut(gas side) for others Coupler heat insulation(gas For indoor side pipe side) joint(gas side) Coupler heat For indoor side pipe insulation(liquid side) joint(liquid side) ●...
  • Page 16: Precaution For Installation

    Precaution for Installation WARNING CAUTION...
  • Page 17: Is The Unit Installed Correctly

    Is The Unit Installed Correctly Installation place Electric work When you change your address or the installation place For inspection and maintenance...
  • Page 18: Installation Procedure

    (When installing at a place under a high humidity environment, pay sufficient attention to the prevention of dewing such as thermal insulation of the unit. ) Ceiling height shall have the following height. Installation space AD71S2SM7FA 100mm 100mm AD100S2SM7FA 50mm...
  • Page 19 Installation Procedure Indoor Unit 1. Preparation for suspending the unit a.Size of hole at ceiling and position of hanging bolts AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA Dimensions A(mm) B(mm) C(mm) D(mm) E(mm) F(mm) Model AD71S2SM7FA 1162 1612 1672 AD100S2SM7FA 1562 2012 2072...
  • Page 20 Installation Procedure Drain Pipe Drain Piping Good piping Improper piping Unit model The size of drain opening For unit without water pump AD71S2SM7FA AD100S2SM7FA 25mm AD125S2SM7FA AD140S2SM7FA For unit with water pump...
  • Page 21 Installation Procedure Drain Pipe Drainage Test Procedures Installation Procedure Air Duct Installation work for air outlet ducts Note Connection of suction, exhaust ducts a.Fresh air inlet b.Exhaust (Make sure to use also the suction.)
  • Page 22 Precautions for electrical wiring Selection of size of power supply and interconnecting wires Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.) AD71S2SM7FA 1U71S2SS5FA AD100S2SM7FA 1U100S2SN5FA AD125S2SM7FA 1U125S2SP5FA AD140S2SM7FA 1U140S2SP5FA POWER SUPPLY &...
  • Page 23: Move And Scrap The Air Conditioning

    Move and scrap the air conditioning...
  • Page 24 You should therefore check with your dealer or Haier’s Customer Care Centre to ensure this fl yer correctly describes the products currently available. Fisher & Paykel Australia Pty Ltd, Level 1, 1 Eden Park Drive, Macquarie Park, NSW 2113.

This manual is also suitable for:

Ad100s2sm7faAd125s2sm7faAd140s2sm7fa