Mechanical and environmental specifications
Mounting bracket color
Pig tail length
Coaxial cable specification
Impedance
Structural return loss
Nominal RTL reference
Dielectric
Dielectric (outer diameter)
Velocity of propagation
Center conductor
Shield #1
Diameter over foil
Shield #2
Outer jacket
Outer diameter
Outer Jacket
Outer Diameter
PLENUM rating
Attenuation dB/100 feet (nominal reference
values)
Installation temperature
Operating temperature
CC pullout
Jacket pullout
Minimum bend radius
Leakage
36
Black
500 mm (19.69 in)
50 ± 2.0 ohms
–16 dB or better from 100-2500 MHz un-terminated sample (direct
bridge method)
–16 dB or better to 6.0 GHz
Foam FEP
2.79 mm ± 0.076 mm (0.110 in ± 0.003 in)
80%
Solid copper, 0.94 mm ± 0.025 mm (0.037 in ± 0.001 in)
Foil, aluminium/poly tape, adhered to dielectric
3.02 mm ± 0.07 mm (0.119 in ± 0.003 in)
Braid, 90% 36-AWG tin/copper
Plenum PVDF, off-white, lead-free, and UV stable
4.52 mm ± 0.15 mm (0.178 in ± 0.006 in)
Plenum PVDF, Off-white, lead free, and UV stable
4.52 mm ± 0.15 mm (0.178 in ± 0.006 in)
CMP(ETL)C(ETL)
•
8.0 dB at 450 MHz
•
12.5 dB at 900 MHz
•
19.6 dB at l.8 GHz
•
23.6 dB at 2.5 GHz
•
23.0 dB at 3.0 GHz
•
27.5 dB at 4.0 GHz
•
31.0 dB at 5.0 GHz
•
35.0 dB at 6.0 GHz
–20°C (–4°F) to +65°C (149°F)
–30°C (–22°F) to +65°C (149°F)
6 pound-force minimum, 16 pound-force maximum
4.5 pound-force minimum on 76.2 mm (3 in) section at 12.7 mm (0.5
in) per minute
12.7 mm (0.5 in) static bend
–90 dB