Advertisement

Quick Links

NAS‐CW01W6
Temperature and Humidity (4 IN
1)
深圳市丽欧电子有限公司
Version1.0.3

Advertisement

Table of Contents
loading

Summary of Contents for NEO NAS-CW01W6

  • Page 1 NAS‐CW01W6 Temperature and Humidity (4 IN 深圳市丽欧电子有限公司 Version1.0.3...
  • Page 2 NAS‐CW01W6 产品配置 Light Value Battery Front Side Signal icon Time Date Humidity Temperature Indicator NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 3 NAS‐CW01W6 two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Water Leakage Detector is a Z‐Wave™ enabled device and is fully compatible with any Z‐Wave™...
  • Page 4: Battery State

    NAS‐CW01W6 Battery compartment (open back cover to install battery) Buzzer There are hanging holes on the back of the device, which can be hung on the wall, cabinet or placed on the desk, windowsill, bedside table and other places with light The battery must be installed correctly in the battery slot which is marked “+”...
  • Page 5 NAS‐CW01W6 Note: 1. Both Smart Wi-Fi mode and AP compatible mode have Bluetooth mode. 2.If the device does not enter the pairing mode after the first power-on, then press the reset button for 6 seconds 3. When the device enters to be configured or switches to be configured mode, a prompt tone will be played Features 1.
  • Page 6: Download App

    NAS‐CW01W6 Illumination Conditions for the Illumination variation description illumination range Rang ( ) variation ( ) 0—99Lux ≥±10Lux 1. The lighting value varies in different intervals. The lighting 100—500Lux ≥±30Lux value will change only when the changing conditions 500—1000Lux ≥±50Lux corresponding interval are met, and the APP will synchronize the lighting 1000—2000Lux...
  • Page 7: Add Equipment

    NAS‐CW01W6 Add Equipment The device is powered on in Smart wifi mode by default (the indicator blinks at short intervals). If the indicator is off, hold down the reset button for 6 seconds and select the mode corresponding to the indicator to add a device 1.Select a device type to add Note: All Wi-Fi products can be added with any Wi-Fi option.
  • Page 8 NAS‐CW01W6 (2)AP compatible mode: Press the reset button to switch device status until the device changes to AP mode, and then add the device (please follow the instructions of APP). 深圳市丽欧电子有限公司 Version1.0.3...
  • Page 9 NAS‐CW01W6 (3) Bluetooth Add: Enable bluetooth to add WiFi temperature and humidity in Bluetooth mode (you can add WiFi temperature and humidity in Bluetooth mode when Smart Config mode and AP mode are to be configured). 1.Bluetooth add method one 2.Bluetooth add method one (...
  • Page 10 NAS‐CW01W6 Main function, working state and record settings 1.APP Main Interface Device settings Alarm clock (Tap enter alarm screen) Environment Environment Humidity Temperature Warm Prompt Ambient illumination value 深圳市丽欧电子有限公司 Version1.0.3...
  • Page 11 NAS‐CW01W6 Temperature, humidity, brightness value data curve Temperature humidity alarm records Smart Settings 二. Temperature, humidity and luminance value data curve (temperature, humidity and luminance value data can be queried on the date of use) 三.APP Record;You can view historical alarm records of added devices in the message center.
  • Page 12 NAS‐CW01W6 三. 四.Smart Scene 五. Setting (temperature scale switch, temperature and humidity alarm setting, buzzer switch, temperature and humidity upper and lower limits setting, alarm clock settings) ① ② ③ 深圳市丽欧电子有限公司 ④ Version1.0.3...
  • Page 13 NAS‐CW01W6 ⑤ ⑥ ⑦ ⑧ ⑨ ① Display the current power status of the battery;(25% will be low battery alarm); ② Temperature scale switch: Switch between degrees Celsius and Fahrenheit: (Before setting, press the reset button to wake up the device); ③...
  • Page 14 NAS‐CW01W6 ④ Temperature and humidity sensitive parameters:data will be reported only when the temperature and humidity value is reached.(Before setting, press the reset button to wake up the device) ⑤ Buzzer switch: can be set to open and close;(Before setting, press the reset button to wake up the device) ⑥...
  • Page 15: Other Functions

    NAS‐CW01W6 ⑧ Upper and lower limits of temperature and humidity (minimum temperature ‐10 ℃ , maximum humidity 60℃, minimum humidity 0%, maximum humidity 100%) ⑨ Alarm management: temperature and humidity alarm push switch, low electric alarm push switch (press reset button to wake up the device before setting); Other Functions 1.Shared Device 深圳市丽欧电子有限公司...
  • Page 16 NAS‐CW01W6 2.Push Management APP all push; If push is disabled, all devices in the APP will not receive push, but message records will not be affected. 3. Clear records; Delete the device through the APP and add the device again to clear the historical record 深圳市丽欧电子有限公司...
  • Page 17 NAS‐CW01W6 Make Your Home Smarter 深圳市丽欧电子有限公司 Version1.0.3...

Table of Contents