InFocus LP600 Replacement Instructions

Replacing the projection lamp
Hide thumbs Also See for LP600:

Advertisement

Quick Links

Replacing the projection lamp

The lamp hour timer in the About menu counts the number of hours the
lamp has been in use. Fifty hours before the specified end of the lamp's life,
the message "Replace lamp" briefly appears on the screen at each startup
and in the Interactive Display. After 50 additional hours, the lamp will no
longer light. You can order new lamp modules from your dealer.
1
Turn off the projector and unplug the power cable.
2
Wait 60 minutes to allow the projector to cool thoroughly.
3
Turn the projector upside down and remove the lamp door by placing a
flat-blade screwdriver into the space between the lamp door and the
projector and gently prying the door off.
4
Loosen the captive screw on the lamp module.
:
To avoid burns, allow the projector to cool for at least 60 minutes before
you replace the lamp.
Unplug the power cord before replacing the lamp.
Do not drop the lamp module. The glass may shatter and cause injury.
Do not touch the glass lamp screen. Fingerprints can obscure projection
sharpness.
Be extremely careful when removing the lamp housing. In the unlikely
event that the lamp ruptures, small glass fragments may be generated. The
lamp module is designed to contain most of these fragments, but use
caution when removing it. Before replacing a ruptured lamp, clean the
lamp compartment and dispose of cleaning materials. Wash hands after
lamp replacement. This product has a lamp which contains a very small
amount of mercury. Dispose of it as required by local, state or federal
ordinances and regulations. For more information see www.eiae.org.
5 Detach the lamp connector from the projector by gently pulling the
connector until it is disconnected from the projector.
6 Carefully remove the lamp module by grasping and lifting the metal
handle. Dispose of the lamp in an environmentally proper manner.
7 Install the new lamp module, making sure that it is properly seated.
Be careful not to touch the interior components of the projector.
8 Snap the handle back into its flat position against the lamp module.
9 Re-attach the lamp connector to the projector. Make sure the
connector is fully inserted.
10 Tighten the screw on the lamp module.
11 Replace the lamp door.
12 Plug in the power cable then press the Power button to turn the
projector
Resetting the lamp timer
If the lamp timer has reached the maximum number of hours for the
projector lamp, the LED on the projector's keypad will show a lamp error
(see "LED behavior and meaning" in the user's guide). To reset the lamp
timer, press the decrease volume button on the keypad and the increase
volume button simultaneously for 10 seconds. You can also navigate to
the Settings>Service menu and select Lamp Reset to reset the lamp timer.
Warnings
Loosen the screw on the lamp module
Use the handle to lift the lamp out
Reset the lamp timer in the Service menu
009-0935-01
Turn off and unplug the projector
Wait 60 minutes
Pry the lamp door off
Unplug the lamp connector.