Download Print this page

Hussmann PWW Datasheet page 3

Hussmann pww merchandisers: data sheet

Advertisement

Wide Island, 1 Display Level
Dimensions are shown as inches & (mm).
PWW
44
(1118)
6
(152)
Front
of
Case
30
/
3
8
(772)
Electrical
25
/
1
2
17
/
3
8
(648)
(441)
17
(432)
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF
P/N 0417990A
15
(381)
33
/
3
4
(857)
FAN
COIL
5
1
/
2
(114)
5
/
7
(149)
8
L C
3
/
1
(89)
2
3
/
1
(89)
2
69
(1765)
86
/
1
2
(2197)
) Standard #7 requirements.
®
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Optional
Rack
Positions
33
/
3
4
(857)
COIL
12
/
3
8
(314)
/
1
2
PWW
Impact
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
Discharge Air (°F)
Evaporator(°F)
Unit Sizing (°F)
Btu/hr/ft*
Parallel
Conventional
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
Frequency (hr)
Defrost Water (lb/ft/day)
(± 15% based on case configuration and
product loading).
O
FFTIME
Temp Term (°F)
Failsafe (minutes)
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO**
Indoor Unit Only, Pressure Defrost
Termination**
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
Liquid Line (in.)
Suction Line (in.)
Estimated Charge (lb)***
4 ft
6 ft
8 ft
12 ft
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by
Each End/Partition (in.)
Produce
PWW
4,6,8,12E
34
24
22
PWW
4,6,8,12E
1200
1325
PWW
4,6,8,12
6
8
PWW
4,6,8,12E
N/A
45
PWW
4,6,8,12E
17°/ 7° F
48° F
1
1
/
2
3
/
8
7
/
8
PWW
4,6,8,12E
1.4
2.3
2.8
4.3
1
1
/
2
3 of 4

Advertisement

loading

This manual is also suitable for:

Impact pww 4eImpact pww 6eImpact pww 8eImpact pww 12e