SAFETY AND WARNINGS WARNING! WARNING! Electrical shock hazard Fitting integrated front panels requires access to Before installing the dishwasher, remove the electrical service areas. house fuse or open the circuit breaker. This work must be performed and certified by a This appliance must be earthed.
SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Installation of this dishwasher requires basic Ensure the product is not plugged in when fitting mechanical and electrical skills. custom panels. Be sure to leave these Instructions with the Customer. Installation of custom panels requires basic mechanical Installation must comply with your local building and and electrical skills.
PRODUCT DIMENSIONS FRONT PROFILE DD60DI DD60DHI PRODUCT DIMENSIONS Overall height of product 1, 2 820-880 Overall width of product Overall depth of product Depth of chassis (to back of front drawer panel) Depth of drawer front panel 16-20 Height of chassis Height of drawer front panels min.
CABINETRY DIMENSIONS Bracket slots PLAN PROFILE DD60DI DD60DHI CABINETRY DIMENSIONS Inside height of cavity* min. 820 Inside width of cavity Inside depth of cavity min. 560 Minimum clearances from adjacent cabinetry Recommended height of adjacent cabinet space Height of toekick space* 100-160 * depending on adjustment of levelling feet min.
Page 8
CUSTOM DRAWER PANEL CALCULATIONS FRONT PANEL MATERIAL SPECIFICATIONS 16 - 20mm panel thickness Adequately sealed to withstand moisture (50 C @ 80% RH) Because of it being a hot and wet environment generally, the back and sides of the panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) to prevent damage to the panel.
Page 9
CUSTOM TOEKICK PANEL CALCULATIONS TOEKICK PANEL MATERIAL SPECIFICATIONS min. 9mm panel thickness if using supplied screws Adequately sealed to withstand moisture (50 C @ 80% RH) You may choose to affix your custom toekick panel either by screwing it or gluing it to the supplied mounting bracket. HEIGHT OF THE TOEKICK PANEL Measure D (height from the top of adjacent cabinet door fronts to the floor) and write it in the first box below, then complete the equation.
CAVITY PREPARATION COUNTERTOP Water Connection Recommended COLD (Maximum 60°C). Moisture 10 mm protection tape 3/4“ BSP (GB20) to must be applied. suit flat washer. Water Pressure Water softener models Max. 1 MPa (145 psi) These marks indicate formed Min. 0.1 MPa (14.5 psi) bracket screw locations, if securing by drawer removal.
Page 11
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses - 2000mm Drain hoses - 1800mm Inlet hose - 1650mm Inlet hose - 1250mm Power cord (excl.plug) - 1650mm Power cord (excl.plug) - 1650mm...
Page 12
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) ATTACH SIDE MOUNTING BRACKETS PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the Clip all four side mounting brackets When fitting brackets, two top mounting brackets...
Page 13
SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE The top mounting brackets will only bend upwards a Open the drawer (x2) maximum of 10mm. halfway. Using a flat bladed screwdriver, prise Replace the grey the grey rubber rubber plug back into plug out of the the trim moulding...
Page 14
ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL PULL THROUGH HOSES & PUSH INTO THE CAVITY REMOVE THE LOWER DRAWER To prevent kinked hoses optionally attach the Either sit the drawer down on the left two top mounting When fitting brackets, hand side (recommended) or rotate the brackets ensure the ends are...
Page 15
SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE The top mounting brackets will only (x2) bend upwards a maximum of 10 mm. For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand Secure using two pairs...
Page 16
INSTALLING CUSTOM FRONT DRAWER PANELS REMOVE BOTH PANEL BRACKETS FROM PRODUCT REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Knock-to-Pause module Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire.
Page 17
INSTALLING CUSTOM FRONT DRAWER PANELS ATTACH KNOCK-TO-PAUSE MODULES ATTACH CUSTOM PANELS TO PANEL BRACKETS TO CUSTOM PANELS There must be at least 3 screws used each side. Align bottom of each custom panel with the bottom of each bracket. IMPORTANT! 16mm (x3) Ensure the Knock-To-Pause module is orientated correctly...
Page 18
INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE RECONNECT THE EARTH WIRE TO THE TO THE CONTROLLER PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g.
Page 19
FITTING A CUSTOM TOEKICK PANEL Custom Toekick Panel Place the Toekick panel cutting template onto your toekick panel. Ensure they are centered and the template rests on the top surface of the panel. Secure template to panel either by clamping or using the supplied mounting screws.
Page 20
FIT THE SUPPLIED PREFINISHED TOEKICK PANEL (IF PREFERRED) Prefinished Toekick Panel Where the toekick meets the bottom of the tub is the cut-off point Lay the toekick face down on Turn the toekick over and Smooth the edge with a file. a chopping board or similiar.
Page 21
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 DRAINAGE OPTION 2 Dishwasher and Ø 38 mm Standpipe Dishwasher using drain hose joiner onto sink trap/waste tee Supplied drain hose joiner to suit Screw Drain hose Screw Drain hose support to back wall...
CONNECT INLET HOSE TO COLD WATER PLUG PRODUCT IN min. 10mm 3/4” BSP connector No leaks! Ensure the supplied rubber washer is fitted Tighten coupling with spanner. inside the coupling. TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arms not in place.
FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Turn on the power and water supplies, then open the drawers. You should hear a Check all parts are installed. beep and see a program indicator light up on the control panel. Ensure that all panels and parts thereof are secure and final electrical tests have Check the spray arms are in place, mounted correctly and free to rotate, by been conducted in accordance with local electrical regulations.
SAFETY AND WARNINGS WARNING! WARNING! Electrical shock hazard Fitting integrated front panels requires access to Before installing the dishwasher, remove the electrical service areas. house fuse or open the circuit breaker. This work must be performed and certified by a This appliance must be earthed.
Page 27
SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Installation of this dishwasher requires basic Ensure the product is not plugged in when fitting mechanical and electrical skills. custom panels. Be sure to leave these Instructions with the Customer. Installation of custom panels requires basic mechanical Installation must comply with your local building and and electrical skills.
Page 28
PARTS SUPPLIED Drain hose Drain hose Wire clip (1) Clamp (1) Side mounting bracket kit Top mounting support (1) joiner (1) (for securing (for securing (A and B) (2) brackets (2) Drain hose joiner) Drain hose joiner) OPTIONAL OPTIONAL Phillips 38 mm Rubber washer Moisture protection...
Page 29
PRODUCT DIMENSIONS FRONT PROFILE TALL TALL HEIGHT HEIGHT (Installed in a (Installed in a STANDARD STANDARD 18” (456mm) 18 7/8” (480mm) HEIGHT HEIGHT high cavity) high cavity) DD60SI DD60STI DD60STI DD60SLI DD60SHI DD60SHTI DD60SHTI PRODUCT DIMENSIONS Overall height of product Overall width of product Overall depth of product Depth of chassis...
Page 30
CABINETRY DIMENSIONS Cavity Bracket (480mm cavity height) Custom Filler Panel (other heights) Bracket slots TALL HEIGHT MODELS ONLY If your cavity height leaves a visible gap under PLAN your countertop when you open the drawer: Fit the supplied cavity bracket (or a custom TALL TALL cavity filler panel) before installation in order...
Page 31
CUSTOM DRAWER PANEL CALCULATIONS FRONT PANEL MATERIAL SPECIFICATIONS min. 2mm 16 - 20mm panel thickness Note: when the top of the dishwasher Adequately sealed to withstand moisture (50 C @ 80% RH) has to be lower than the adjacent Because of it being a hot and wet environment generally, the back and sides of the cabinetry, the top of the panel can panel should be completely sealed with a waterproof vapour barrier (ie polyurethane) extend above the chassis where required,...
Page 32
CAVITY PREPARATION COUNTERTOP Moisture 10 mm protection tape must be applied Water Connection Recommended COLD (Maximum 60°C). These marks indicate formed bracket screw locations, if 3/4“ BSP (GB20) to securing by drawer removal. suit flat washer. If there is no side partition, you Ø...
Page 33
PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET External Venting Kit Services can be located (Excludes DD60SLI9 models) either side of dishwasher Shelf cutouts max. 5mm VENT HOSE ø 57mm ø 57mm IMPORTANT! ø 57mm To prevent pooling of condensation from the vent hose, a toekick height of no less than 100mm is required.
Page 34
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hose - 1800mm Drain hose - 2000mm Inlet hose - 1650mm Inlet hose - 1250 mm Power cord (excl.plug) - 1650mm Power cord (excl.plug) - 1650mm Venting hose - 1525mm Venting hose - 1925mm TALL HEIGHT INTEGRATED MODELS FOR 480 MM CAVITY ONLY - ATTACH CAVITY BRACKET...
Page 35
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) ATTACH SIDE MOUNTING BRACKETS ATTACH VENTING HOSE Clip all four side mounting brackets into their slots using a flat-bladed screwdriver.
Page 36
PULL THROUGH HOSES & MOVE INTO THE CAVITY SECURE TO THE CABINETRY ON THE SIDES Open the drawer halfway. Using a flat bladed Replace the grey screwdriver, rubber plug back into prise the grey the trim moulding rubber plug out and ensure the trim of the trim seal is facing forward.
Page 37
ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL ATTACH VENTING HOSE PULL THROUGH HOSES & MOVE INTO THE CAVITY Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it.
Page 38
REMOVE THE DRAWER SECURE TO THE CABINETRY ON THE SIDES To prevent kinked hoses The product has three Either sit the drawer down on the left hand pairs of fixing points: side (recommended) or rotate the drawer clockwise, resting it on its side after removal. Ensure the sound insulation is repositioned correctly.
Page 39
REFIT THE DRAWER ONTO THE RUNNERS Lift or rotate anti-clockwise the drawer back onto the drawer runners on either side. Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of Pull the release tabs forward on both each drawer runner are sides 100 mm.
Page 40
INSTALLING A CUSTOM FRONT DRAWER PANEL REMOVE PANEL BRACKET FROM PRODUCT REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is Knock-to-Pause module disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire.
Page 41
INSTALLING CUSTOM FRONT DRAWER PANELS ATTACH KNOCK-TO-PAUSE MODULE ATTACH CUSTOM PANELS TO PANEL BRACKETS TO CUSTOM PANEL There must be at least 3 screws used each side. Align bottom of each custom panel with the bottom of each bracket. 16mm (x3) IMPORTANT! Ensure the Knock-To-Pause module is orientated correctly...
Page 42
INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE RECONNECT THE EARTH WIRE TO THE TO THE CONTROLLER PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g.
Page 43
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 DRAINAGE OPTION 2 Dishwasher and Ø 38 mm Standpipe Dishwasher using drain hose joiner onto sink trap/waste tee Supplied drain hose joiner to suit Screw Drain hose Screw Drain hose 19 mm waste tee...
Page 44
CONNECT INLET HOSE TO COLD WATER PLUG PRODUCT IN min. 10mm 3/4” BSP connector No leaks! Ensure the supplied rubber washer is fitted inside the coupling. Tighten coupling with spanner.
Page 45
TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place. No water supply.
Page 46
FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Turn on the power and water supplies, then open the drawer. You should hear a Check all parts are installed. beep and see a program indicator light up on the control panel. Ensure that all panels and parts thereof are secure and final electrical tests have Check the spray arms are in place, mounted correctly and free to rotate, by been conducted in accordance with local electrical regulations.