Commissioning - Interlogix SP1083600 Installation Manual

Motor-driven blocking device easylock
Table of Contents

Advertisement

Available languages

Available languages

Figure 8: Connecting several blocking devices in series

Commissioning

When impressing the operating voltage on the blocking device will open up in
any case independent from the status of the inputs.
Functional check:
Close and open the blocking device when the door is closed. In doing so,
check the following functions:
- Closing or opening time maximum about 1/2 second.
- The locking bolt must neither contact nor interlock on the counterpart. The
locking bolt extends without several locking trials.
- The locking bolt can extend at full length since otherwise it would open up
again after several locking trials.
If the functionality is incorrect then check the wiring on the basis of the signal
descriptions and the examples for switching on described in "Connection" on
page 10.
12
SP1083600 Motor-Driven Blocking Device EasyLock Installation Manual

Advertisement

Chapters

Table of Contents
loading

Table of Contents