8. Adjustment Procedure
8.1. Driver Set-up
8.1.1. Item / Preparation
1. Input an APL 100 % white signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Cool
Aspect: 16:9
8.1.2. Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Name
Test
Point
Vsus
TPVSUS
173V ± 2V
(SS)
Vset
TPVSET
220V ± 5V
(SC)
Vbk
TPVBK
140V ± 1V
(SC)
Vad
TPVAD
-85V ± 1V
(SC)
Vscn
TPVSCN
Vad*+118V
(SC)
± 2V
Ve
TPVE
150V ± 1V
(SS)
Vda
TPVDA
75V ± 1V
(SS)
*See the Panel label.
8.2. Initialization Pulse Adjust
1. Input a Cross hatch signal.
Voltage
Volume
VR641 (P)
---
R6670
(SC)
R6477
(SC)
---
R6770
(SS)
VR665 (P)
Remarks