5.1.8. HOW TO INITIALIZE MEMORY IC
After the Memory IC (IC6004) or TV/VCR Main C.B.A. is replaced, be sure to set the Default value
to Memory IC as shown in "Memory IC Reference Table" below.
1. Press and hold STOP, PLAY, and VOL- buttons on the unit
together over 5 seconds with no cassette inserted.
The adjustment overlay will appear to Enter EVR Adjustment
mode.
2. Press ACTION key on the remote and VOL- button of operation
panel on the unit together. The overlay color will be changed from
red to green. (All Control functions are displayed.)
3. Set the Default value of all Control functions using a remote
control as shown in "Memory IC Reference Table."
Note:
For Selecting Control functions and setting Default value, refer to "
How to
adjust:" of How to enter EVR adjustment mode in
ADJUSTMENT PROCEDURES.
Fig. 4
Fig. 5-1
Fig. 5-2