Download Print this page

Viking VK1812 User Manual

Led par 5in1 rgbwa

Advertisement

Quick Links

VK1812 & VK2412 BLAZE
LED Par
5in1 RGBWA
User Manual

Advertisement

loading

Summary of Contents for Viking VK1812

  • Page 1 VK1812 & VK2412 BLAZE LED Par 5in1 RGBWA User Manual...
  • Page 2 Thank you for purchasing LED Tour Par 18, Every unit has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact.
  • Page 3: Installation

    is subject to change without notice. We reserves the right to modify and upgrade its range of products, with no obligation to integrate these changes into products already sold. Warning To prevent or reduce the risk of electrical shock or fire ,do not expose the unit to rain or moisture.
  • Page 4 Features and Specifications • Light Source: 24 x 12W RGBWA 5in1 LED • Beam Angle: 25 ° (Other optional) • DMX channel: 1/5/6/7/13 channels • 4 Dimmer Curve • Display: OLED touch display • Data In/Out: 3-pin or 5-pin XLR IP65 •...
  • Page 5 Product View RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION! FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT FROM THE UV LED. WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE TO THE UV LED. AVOID WEARING WHITE COLOUR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
  • Page 6: Control Panel

    Product View Control Panel The control panel is the mechanism for configuring the LTP12 settings. It has a small LCD screen and four buttons, which are described below. Button Function Scrolls through the first level of options, or exits from the current menu or <MENU>...
  • Page 7 DMX Set Up DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN”...
  • Page 8 Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -).
  • Page 9 Product View All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen”...
  • Page 10 Menu Structure Address 001-512 Mode 13CH Program 1 000-255 Program 2 Speed 000-255 Auto Program 3 ..Program 12 Color Off 000-005 ColourMacro Color1~35 006-255 Dimmer 000-255 Stand Alone Strobe 0~30Hz 000-255 Manual Green 000-255 Blue 000-255 White 000-255 Amber 000-255 Dimmer 000-255...
  • Page 11 Output Set Standard Normal output Full Full output AutoLock Dimmer Response Halogen 900Hz 1000Hz 1100Hz 1200Hz 1300Hz 1400Hz PWM Rate 1500Hz 2500Hz 4000Hz 5000Hz 6000Hz 10000Hz Code: down, down, down, up, down, Reset Passcode down,down, up Service Code: down, up, down, up, down, down, down, Calibration Passcode...
  • Page 12 DMX Channels 1 DMX Channels: VALUES FUNCTIONS 1 CH 000-255 Master dimmer 0~255 5 DMX Channels: VALUES FUNCTIONS 6 CH 000-255 RED 0%-100% 000-255 GREEN 0%-100% 000-255 BLUE 0%-100% 000-255 WHITE 0%-100% 000-255 Amber 0%-100% 6 DMX Channels: VALUES FUNCTIONS 7 CH 000-255 RED 0%-100%...
  • Page 13 7 DMX Channels: VALUES FUNCTIONS 8 CH 000-255 RED 0%-100% 000-255 GREEN 0%-100% 000-255 BLUE 0%-100% 000-255 WHITE 0%-100% 000-255 Amber 0%-100% 000-255 Master Dimmer 0~255% SHUTTER & STROBING 000-031 LED Off 032-063 LED On 064-095 Strobing Slow - Fast 096-127 LED On 128-159...
  • Page 14: Dimmer Modes

    128-159 Pulse Strobing 160-191 LED On 192-223 Random Strobing Slow - Fast 224-255 LED On COLOUR MACROS 000-007 No Effect 008~255 Colour MACROS Auto Programs 000-019 No function 020-039 Program 1 020-039 Program 2 020-039 Program 3 020-039 Program 4 020-039 Program 5 020-039...
  • Page 15 061-080 Architectural 081-100 Theatre 101-120 Stage 2 DIMMER DELAY TIME 0.1Sec. 0.2Sec. 0.3Sec. 0.4Sec. 0.5Sec. 0.6Sec. 0.7Sec. 0.8Sec. 0.9Sec. 1.0Sec. 1.5Sec. 2.0Sec. 3.0Sec. 4.0Sec. 5.0Sec. 6.0Sec. 7.0Sec. 8.0Sec. 9.0Sec. 10Sec. 141-255 Default to Unit Setting Refresh Rate 000-010 No Function 011-020 900HZ 021-030...
  • Page 16 Troubleshooting Following are a few common problems that may occur during Operation. Here are some suggestions for easy troubleshooting: 1. The unit does not work,no light and the fan does not work a. check the connection of power and main fuse. b.
  • Page 17: Warranty

    4. One of the channels is not working well a. The stepper motor might be damaged or the cable connected to the PCB is broken. b. The motor’s drive IC on the PCB might be out of condition 5. Fixture Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
  • Page 18 Any modification to the fixture will void the warranty. We cannot under any circumstances be held liable for quality and conformity regarding the installation of this product, which is the responsibility of the installer. the device and before use, may be covered by the warranty. The manufacturer is not responsible for any errors or omissions that may occur in this document.