TABLE 2

CLEARANCES

Front
Back
Left Side(Filter Access)
Right Side
Below Unit
Above Unit
Units must be installed outdoors. Over-hanging structure
or shrubs must not block the condenser fan outlet.
Units may be installed on class A, B or C roof covering.

Power Supply Considerations

The installer shall check available power to make certain it
matches the unit rating plate and that constant voltage can
be maintained on the unit. Unsatisfactory performance or a
possible hazard could otherwise result. The local power
company should be contacted with questions concerning
power supply.

Ground Level Installation

Location

Placement of the unit should be in a well-drained area, or
the unit must be supported high enough so run-off will not
enter the unit.
The air outlet should be located so as to direct discharged air
away from the building. A minimum of six feet clearance
above the unit is required to avoid recirculation. Avoid
locating unit under low overhanging roofs.
Avoid installations under roof overhangs without guttering.
Water draining from the roof onto the unit could produce
excessive noise and may cause ice build-up during cold
weather.
Locate unit away from windows, patios, decks, etc. where
unit operation sound may disturb customer.
Do not locate where heat, lint or exhaust fumes will be
discharged on the unit.

Side Mounted Supply and Return Air Openings

Units are shipped from the factory for side mounted
installation supply and return air applications.
Be sure to note supply and return openings before
installation.
36"
2"
24"
"
24
0"
72"(For condenser
air discharge)
Field supplied
disconnect switch
located to rear of unit
4
To power supply
Control wiring to
indoor thermostat
Return air duct
Supply
air duct