Wiring Diagram With Integrated Control 107048-XX
120V ACC
G
(IF USED)
N
L1
7
HUMIDIFIER
S1
ROOM THERMOSTAT
W2
W1
G
R
C
Y1
Y2
OUTDOOR
UNIT
Y1
Y2
C
L
S51
DOOR
INTERLOCK
L1
7
K4
K1
P3
P3
J3
J3
2
3
P84
3
2
J84
B6
B6
J84
J159
1
P84
P159
J3
4
P3
N
N
N
N
7
EQUIPMENT
GROUND
S10
PRIMARY
COMBUSTION AIR
B6
GAS
INDUCER MOTOR
J84
LIMIT
P84
BURNERS
6
S47
FLAME
IGNITOR
FLAME
SENSOR
ROLLOUT
SWITCH
SEE HUM VIEWS
L1
ACC
S51
HUM
SEVEN
A92
SEGMENT
INTEGRATED
LED
CONTROL
1 2 3 4
5 6 7
8
DIAGNOSTIC
PUSH
BUTTON
W1 W2 G
Y2
TERMINAL BOARD
A92
INTEGRATED CONTROL
L1
LINE
HOT
24VAC
SEC
P2
5
J2
8
K7
K5
K11
GV1
GAS
C
VALVE
1
CB8
P159
1
J159
120V
T1
ACC
2
YEL
J3
5
P3
A92
INTEGRATED
CONTROL
N
N
LINE VOLTAGE FIELD INSTALLED
CLASS II VOLTAGE FIELD WIRING
DENOTES OPTIONAL COMPONENTS
C
GV1
GAS
HI
VALVE
M
S102
HIGH HEAT
PRESSURE
SWITCH
S128
S47
R33
LOW HEAT
FLAME
PRESSURE
J159
ROLLOUT
SWITCH
P159
SWITCH
J3
T1
NEUTRALS
TRANSFORMER
CB8
4
J2
L13
CIRCUIT
BREAKER
POWER
CHOKE
B3
8
P48
C
R DH
H
L O
DS
Y1
P49
INDOOR
TB1
BLOWER
MOTOR
K8
12
6
11
11
4
4
10
7
2
1
(2) S47
M
(1) S47
NO
NO
HI
C
C
S10
LENNOX
HEATING UNITS−GAS
EL296DF045XE36B
EL296DF090XE48C
EL296DF070XE48B
EL296DF110XE60C
EL296DFXE
2 HEAT 2 COOL
Supersedes
2011
Litho U.S.A.
C
FIGURE 61
Page 47
UNIT
HI COOL
LOW COOL
HIGH HEAT
LOW HEAT
9
DF045XE36B
BLACK
BROWN
BLUE
YELLOW
BLUE
DF070XE48B
BLACK
BROWN
YELLOW
DF090XE48C
BLACK
BLUE
BROWN
YELLOW
BROWN
DF110XE60C
BLACK
BLUE
YELLOW
BLOWER SPEED SELECTION
HI
LOW
SPEED TAPS
BLACK
BROWN
BLUE
YELLOW
TO C
HUMIDIFIER
TO R OR H ON CS7000
HUM
AT IFC
TO N
HUMIDIFIER
J,P48
TO L1
J,P49
HUM
J,P2
AT IFC
J,P84
J,P3
1
CUT W914 JUMPER LABELED DEHUM FROM DS
J,P159
TO R, AT A92 CONTROL BOARD, WHEN USED
WITH ComfortSense
R
7000 THERMOSTAT
DIP SWITCH FACTORY DEFAULT IS FOR A TWO
5
CUT W951 JUMPER FROM O TO R, LABELED
STAGE THERMOSTAT
2
"HEAT PUMP", AT A92 CONTROL BOARD, WHEN
6
FIELD SUPPLIED ACC WIRE
USED FOR DUAL FUEL APPLICATIONS
7
USE COPPER CONDUCTORS ONLY
CUT W915 JUMPER LABELED "2 STAGE COMPR."
3
FROM Y1 TO Y2 AT A92 CONTROL WHEN USED
DH AND L TERMINALS NOT USED.
8
WITH A 2 STAGE COOL THERMOSTAT.
9
DO NOT USE RED (LOW SPEED) FOR HIGH
L13 USED ON 3/4 AND 1 HP ONLY
4
HEAT ON ALL MODELS.
THERMOSTAT HEAT ANTICIPATION SETTING
HONEYWELL VALVE
.65 AMP
TWO STAGE
.43 AMP
WHITE RODGERS VALVE
HEAT,COOL
NOTE: SEE INSTALLATION INSTRUCTIONS FOR PROCEDURE
TO SET CORRECT BLOWER SPEED FOR SPECIFIC COOLING
TONNAGE BEING APPLIED, AND HEATING TEMPERATURE
RISE REQUIRED.
TYPICAL SYSTEM SHOWN FOR 2 HEAT/2 COOL WITH A
CONVENTIONAL THERMOSTAT. SEE INSTALLATION
INSTRUCTIONS FOR CONNECTIONS TO OTHER EQUIPMENT
AND ACCESSORIES.
24−V
COM.
9
9
3
SEE BLOWER SPEED CHART
1
2
3
4
5
J49
1
2
3
4
5
P49
WHT/BLK
C
BLACK
B3
L
INDOOR
BLOWER
GN/YLW
G
MOTOR
WHT
N
P48
J48
WARNING−
ELECTRIC SHOCK HAZARD,CAN CAUSE INJURY
OR DEATH.UNIT MUST BE GROUNDED IN ACCORDANCE
WITH NATIONAL AND LOCAL CODES.
NOTE−
IF ANY WIRE IN THIS APPLIANCE IS REPLACED,IT
MUST BE REPLACED WITH WIRE OF LIKE SIZE,
RATING, INSULATION THICKNESS, AND TERMINATION
PARK
RED
RED
RED
RED
RED
JACKPLUG CHART
JACK/PLUG−INDOOR BLOWER−POWER
JACK/PLUG−INDOOR BLOWER−SPD TAP
JACK/PLUG−BURNER CONTROL
JACK/PLUG−COMB AIR INDUCER
JACK/PLUG−INDUCER/IGNITER
JACK/PLUG−IGNITION
S1
ROOM THERMOSTAT
R
ON
FAN
COOL
HEAT
COOL
2
2
C
W2
Y2
W1 Y1
G
R
W2
Y2
W1
Y1
O
G
C
DS
W915
2
3
1
W914