6 Wiring Diagram

6.1.
Resistance of Fan Motor
windings and the rated
Capacitor
Model
CW-XC100VK
Connection
CWA951216
34.6 Ω
Blue - Yellow
2.3 Ω
Yellow - Brown
13.7 Ω
Brown - Orange
36.6 Ω
Red -Yellow

7 Air Conditioner Performance Evaluation

Suction & Discharge Air
Temperature Difference
• 8°C and over (14.4°F)
• 8°C and over (14.4°F)
• Under 8°C (14.4°F)
• Under 8°C (14.4°F)
• Under 8°C (14.4°F)
Note: Room air humidity is relatively higher, the temperature difference will be smaller.
CW-XC120VK
CWA951215
34.8 Ω
2.5 Ω
14.8 Ω
37.6 Ω
Current
• As specified.
• Higher than specified.
• Higher than specified.
• Lower than specified.
• Higher than specified by
50%.
6.2.
Resistance of Compressor
windings and the rated
Capacitor
Model
CW-XC100VK
Connection
CWB09623
0.690 Ω
C-R
2.429 Ω
C-S
Capacitor
CWA312066 (40µF,
250VAC)
Note: Resistance at 20°C of Ambient Temperature.
Determination
• Nothing wrong.
• Nothing wrong, outdoor
temperature is too high, heat
radiation is not efficient.
• Something is preventing heat
radiation.
• Leakage of refrigerant or
refrigerant system is blocked.
• Compressor defect.
7
CW-XC100VK / CW-XC120VK
CW-XC120VK
CWB09624
0.724 Ω
2.168 Ω
CWA312067 (45µ,
250VAC)
Remedy
• None.
• Improve heat radiation.
• Excessive amount of refrigerant.
• Improve heat radiation.
• Locate and repair leak.
• Flush refrigeration cycle.
• Replace the compressor.