Assembly - Image RENEW 615 User Manual

Hide thumbs Also See for RENEW 615:
Table of Contents

Advertisement

Assembly

Before beginning assembly, carefully read the
following information and instructions:
• Place all parts in a cleared area and remove the
packing materials from the spa shell. Do not dis-
pose of the packing materials until assembly is
completed and the spa is operating.
• During assembly, make sure that all parts are
oriented as shown in the drawings.
• Read each assembly step before you begin.
• Tighten all parts as you assemble them, unless
instructed to do otherwise.
1. Before beginning assembly, make sure that you
have read and understand the information in the
box above and on the previous two pages.
Remove the eight 1/4" x 1 1/2" Machine Screws (7)
from the Access Panels (2, 5). Remove the Access
Panels by sliding them down and then pulling the bot-
tom away from the spa. Be careful not to damage
the spa shell.
You may want to snap the three included pillows into
position at this time. Each pillow can be attached to
the spa shell in a high or low position. To determine
high or low position, attach a pillow to the spa shell,
note its position, remove the pillow, turn it 180
reattach it.
2. Refer to the drawing on page 6 and locate the pump
access opening. Locate the drain hose inside the
spa. Close the valve knob on top of the drain hose.
Next, make sure that the cap is fully tightened onto
the end of the drain hose.
Locate the the two indicated gate valves inside the
pump access opening. Make sure that the gate
valves are open and that the locking clips are
snapped onto the stems of the gate valves (refer to
the inset drawing at the right).
Make sure that the two indicated collars are tight-
ened.
Refer to step 1 above. Re-attach the pump Access
Panel (2) to the spa with the four 1/4" x 1 1/2"
Machine Screws (7).
ASSEMBLY REQUIRES THE FOLLOWING
TOOLS (not included):
• One (1) phillips screwdriver
• You may also need a small amount of soap
or water.
A wire connector is provided on the electronics
pack of the spa to connect a minimum No. 8
AWG (8.04 mm
between the spa and any metal equipment,
electrical enclosure made of metal, metal water
pipes, or conduit within five feet of the spa.
1
Spa Shell
Pillow
5
o
and
7
2
Locking
Clip
Stem
Gate Valve
8
2
) solid copper conductor
Pillow
Spa Shell
Gate Valve
Cap
Valve
Knob
Pillow
2
7
Collars
Gate
Valve
Drain
Hose

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imhs61500

Table of Contents