Samsung WA48H7400AP Service Manual page 22

Top-loading type
Hide thumbs Also See for WA48H7400AP:
Table of Contents

Advertisement

Error Type
For USA
Power Error
9C1,9C2
AC
AC3
Communication
AC4
Error
AC5
AC6
Switch Error
(Main Relay
bC2
Error)
20 _ Troubleshooting
-
Check the consumer's power conditions.
:
Make sure to check the operating voltage. Connect a
tester to the internal power terminals during the Boil or Dry
operations and observe the washing machine's operation
carefully.
:
Check the voltages.
(An error occurs when under or over voltage is supplied.)
:
Check whether a plug receptacle is used.
When the connecting wire is 1m, a momentary low voltage
may drop up to 10 V
-
Main PBA fault (sometimes)
-
The signals between the sub and main PBAs are not sensed
because of commuication error.
-
Check the connector connections between the sub and main
PBAs carefully.
→ Check for incorrect or loose connections, etc.
-
Remove the sub PBA C/Panel and check for any faulty
soldering.
-
The signals between The DR Module and main PBAs are not
sensed because of commuication error.
-
Check The connector connections between The DR Module
and main PBAs carefully.
→ Check for incorrect or loose connections, etc.
-
Remove The DR Module and Check for any faulty soldering.
-
The signals between The WIFI Module and main PBAs are not
sensed because of commuication error.
-
Check The connector connections between The WIFI Module
and main PBAs carefully.
→ Check for incorrect or loose connections, etc.
-
Remove the WIFI Module and Check for any faulty soldering.
-
The signals between The LCD Module and main PBAs are not
sensed because of commuication error.
-
Check The connector connections between The LCD Module
and main PBAs carefully.
→ Check for incorrect or loose connections, etc.
-
Remove The LCD Module and Check for any faulty soldering.
-
The signals between the Inverter PBA and main PBA are not
sensed because of communication error.
-
Check The connector connections between the Inverter PBA
and main PBA carefully.
→ Check for incorrect or loose connections, etc.
-
Remove the Inverter PBA and Check for any faulty soldering.
-
The Power button is pressed continually.
(for more than 12 seconds).
-
A switch is jammed or stuck due to be pressed unevenly due to
deformation of the control panel or button.
-
This error may occur when the screws that hold the sub PBA in
place are tightened too much.
-
A button other than the Power button is continually pressed.
(for more than 30 seconds).
-
Deformation of an internal plastic injection part.
-
A screw for assembling the sub PBA is tightened too much.
Causes
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents