Narada Power Source Co., Ltd. REXC operation manual V1.2 Safety and Warning Please read this manual! It provides very important direction for fix and operation, which can make best capability for the equipment, and elongate the using life. For your safety, please do not try to dismantle or open the equipment. The equipment does not contain any spare parts for you.
REXC operation manual V1.2 Chapter One Introduction of REXC series REXC series battery is designed for renewable energy sources such as wind power and solar system, and developed for home energy system with long life, high energy efficiency, superb security and reliability characteristic, which can be applied to energy storage system, telecom and generator, etc.
Narada Power Source Co., Ltd. REXC operation manual V1.2 and another option is copper bar connector. Assure the good connections of post and connectors and low connection resistance; Combination of suppleness and rigidity for more flexible connections; 1.8 Flexible and convenient installation, slinky outside looking Shockproof blocking assembling Satisfy customer’s individual requirements and provide up to 8-class shockproof...
Narada Power Source Co., Ltd. REXC operation manual V1.2 5.Lead Carbon Working Principle Fig.1-2 Lead carbon battery working principle sketch map It forms a new active center in negative electrode by adding active carbon, that can reduce lead deposition overpotential, the lead sulfate will be translated into lead more easily.
Narada Power Source Co., Ltd. REXC operation manual V1.2 Also special alloy grid is chosen to increase vent hydrogen over-potential gassing on the negative plate, which prevents generation of hydrogen. Otherwise, the oxygen generated from positive diffuses through separator to the negative and the oxygen gas reacts quickly and is recombined into water.
Narada Power Source Co., Ltd. REXC operation manual V1.2 Charge voltage 2.30 Charge capacity 2.25 100% discharge 2.15 50% discharge 2.05 Charge current Time ( h ) Fig.2-2 Charge characteristic curve 3. Internal Resistance and Short-Circuit Current The internal resistance of the battery is a dynamic nonlinear parameter that is continuously changed along with the temperature and discharge state.
Narada Power Source Co., Ltd. REXC operation manual V1.2 Chapter Three Operation and Maintenance 1. Parameters Setup Table3-1 Energy storage system parameter setup table (600V system) Parameter name Unit Grid Off-grid V/cell Floating Voltage per cell 2.25 2.25 V/cell Equalization Voltage per cell 2.30...
Narada Power Source Co., Ltd. REXC operation manual V1.2 1.97 I<0.025C ≤I<0.05C 0.025C 1.92 ≤I<0.1C 1.87 0.05C ≤I<0.2C 1.83 0.1C ≤I<0.5C 1.75 0.2C If the battery is not recharged in time after discharge, or the power is off again during recharge, the insufficient-charged batteries will be frequently discharge, thus the batteries will lose part of capacity in short period.
Page 12
Narada Power Source Co., Ltd. REXC operation manual V1.2 decreases from 25 ℃ to 0℃; And too low temperature will cause battery long term insufficient charged, also will make negative plates sulfate and make battery unable to discharge. The capacity will increase at some range when temperature rises. For example the capacity will increase 5% if temperature raises from 25℃...
Page 13
Narada Power Source Co., Ltd. REXC operation manual V1.2 Floating and equalization setting voltage at different temperature ℃) Temperature ( Fig. 3-2 The Voltage Setting Curve Vs. Ambient Temperature If the voltage lower than 2.225 or higher than 2.35 after temperature correction, the suggesting adopted can be charging by 2.25V or 2.35V directly without using temperature compensation.
These data cannot replace loading test to judge whether battery is good. Narada recommend to test these data on the surface or side of battery post. If there are several pairs of post, please test on nearest pair of post.
Page 15
Narada Power Source Co., Ltd. REXC operation manual V1.2 equalization charge voltage, meanwhile, the current is reduced, till the charge finished. The charging time is 24 hours. 4.2 Charge after discharge After discharge, the batteries should be charged in time. The charge method is constant current limit voltage as follows: charge with constant current of 0.1C...
Page 16
Narada Power Source Co., Ltd. REXC operation manual V1.2 1 Charging mode: equalizing charge; 2 Charging voltage: (2.30± 0.002)V/cell; 3 Charging current limited: 0.05C 4 Cut-off condition: the charging current is less than 0.005C with another extended 3 hours or charging time reached 24 hours (alternative);...
5. Storage The storage area of REXC series batteries must be clean, ventilated, dry and without direct sunshine. All lead acid batteries lose capacity when standing on open circuit because of self-discharge. The result is that the voltage of open circuit is decreased, and the capacity also decreased.
Page 18
Narada Power Source Co., Ltd. REXC operation manual V1.2 6.4 Operation and Maintenance Precautions Insufficient Charge If the floating voltage is not set correctly (too low or not compensate according to temperature), the battery system will in an insufficient charge state for a long period of time.
Narada Power Source Co., Ltd. REXC operation manual V1.2 After-sales Service / Customer Service Hotline P.R. China: Asia Pacific: Narada Power Source Co., Ltd. NARADA ASIA PACIFIC PTE.LTD. 9F, Building A, No. 50 Zijinghua Road, 65 Ubi Crescent #07-05 Hola centre,...
Narada Power Source Co., Ltd. REXC operation manual V1.2 Annex 1 VRLA Battery Regular Maintenance Record Type Place Status Number of battery Current (A) Temperature Total Voltage(V) Voltage(V) Voltage(V) Check by sight Result: Tester: Date:...