Nasco Lifeform LF01121U Instruction Manual

Nasco Lifeform LF01121U Instruction Manual

Advanced injection arm

Advertisement

Quick Links

Advanced Injection Arm
LF01121U & LF01126U
Instruction Manual
CAUTION: PRODUCT CONTAINS DRY
NATURAL RUBBER!
Products by Nasco
NP097_95_LF01121U_LF01126U_AdvancedInjectionArm.indd 1

Advertisement

loading

Summary of Contents for Nasco Lifeform LF01121U

  • Page 1 Advanced Injection Arm LF01121U & LF01126U Instruction Manual CAUTION: PRODUCT CONTAINS DRY NATURAL RUBBER! Products by Nasco NP097_95_LF01121U_LF01126U_AdvancedInjectionArm.indd 1...
  • Page 2 However, if instruction with larger needle sizes is required, this can be done; the skin and veins will merely need to be replaced sooner. The Skin and Vein Kits are available through Nasco (see list of supplies). List of Components Advanced Injection Arm Simulator (LF01121U –...
  • Page 3 Subcutaneous and intramuscular Intradermal injection sites (3) injection site Venous Channels Beneath the Skin Figure 1 Realism Life/form ® 8 Fluid Lines Internal Structure (See figure 1.) Image shows the arm without the skin. Internally the vascular structure (dry natural rubber tubing) includes the basilic, median, accessory cephalic, and metacarpal veins.
  • Page 4 Figure 2 Figure 3 General Instructions for Use A. Pressurizing the Veins with Synthetic Blood: Add 1 pint of distilled water to the pint bottle with blood powder; shake it to mix. Be sure the clamp on the fluid supply bag A tubing is closed, fill it with the blood and hang the bag no more than 18"...
  • Page 5 Figure 4 Figure 5 Figure 6 With the other shoulder tube attached to the second (empty) fluid supply bag B, (see Figure 4) gradually “flush” the vascular system with synthetic blood by slowly opening the clamp on fluid supply bag A. (See Figure 5.) (The pinch clamp on fluid supply bag B should be open.) Allow same “blood”...
  • Page 6 Figure 7 The arm is now ready to perform injections or withdrawals along any of the 8 fluid lines present in the arm. Nasco recommends the use of small diameter needles for these procedures; 20 to 25 gauge. Use only distilled water to prep the injection sites and as an injection. A realistic flashback will occur when the vein has been properly punc- tured.
  • Page 7 Figure 9 Open the clamp on the infusion solution or fluid supply bag C. Proof of proper procedure will be evidenced by the flow of fluid from the infusion solution or fluid supply bag C. (See Figure 9.) Note: This procedure may dilute your simulated blood solution. D.
  • Page 8 Figure 12 Figure 14 Figure 13 Figure 15 Care of the Intradermal Sites Puncturing the skin with needles forms small slits or cuts witch will even- tually lead to deterioration. Should leakage occur, perform the following steps: Using the supplied Intradermal Sealant (component J) and supplied 22-guage syringe, remove the needle end of the syringe by twisting at the luer lock.
  • Page 9 Cleaner to the stained area and wipe clean with a soft cloth or paper towel. C. Maintaining the Simulator Nasco Vein Tubing Sealant Kit (LF01099U) will extend the useful life of the tubing. Note: Nasco Vein Tubing Sealant cannot be shipped outside of the United States..
  • Page 10 Check correct positions in the instruction manual for LF01122U Advanced IV Arm Skin and Vein Replacement Kit. Contact Nasco for a FREE instructional video. Check for air bubbles: Make sure you purge the arm of air bubbles. Gradually “flush” the system with synthetic blood by slowly opening the supply clamp.
  • Page 11 LF01123U Black Skin & Vein Replacement Kit LF01124U Vein Replacement Kit LF01130U Fluid Supply Bag LF09919U Nasco Cleaner Actual product may vary slightly from photo. Nasco reserves the right to change product color, materials, supplies, or function as needed. NP097_95_LF01121U_LF01126U_AdvancedInjectionArm.indd 11...
  • Page 12 LF03637U Infant IV Arm Simulator LF03636U Infant IV Leg LF00995U Arterial Puncture Arm Fort Atkinson 901 Janesville Avenue, P .O. Box 901 Fort Atkinson, Wisconsin 53538-0901 1-800-558-9595 eNasco.com • E-mail: lifeform@eNasco.com COPYRIGHT © NASCO 1982 PRINTED IN U.S.A. NP097-95/RV 12-14 NP097_95_LF01121U_LF01126U_AdvancedInjectionArm.indd 12...