TECHNICAL SPECIFICATIONS

Power supply voltage
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
ONLY FOR SERVICE CENTERS USE
THE WIRING DIAGRAM IS LOCATED INSIDE THE UNIT.
LIMIT CONDITIONS
Room temperature for air conditioning 61° ÷ 95°F (16-35 °C)
Maximum relative humidity
Please note: outside of these conditions, the unit will take longer
or may not reach the cooling temperature that is set.

TROUBLESHOOTING

PROBLEM
The air conditioner does not come on
The air conditioner works for a short
time only
The air conditioner works, but does not
cool the room
During operation, there is an unpleasant
smell in the room
The air conditioner does not operate for
about three minutes after restarting it
One of the following messages is
displayed: Lt/ Ht / Lh / PF / HL
see rating label on the product
"
"
"
80% RH
CAUSE
it is not plugged into the outlet
there is no power
the internal safety device has tripped
there are bends or kinks in the air
exhaust hose
something is preventing the air from
being discharged
windows, doors and/or curtains open
there are heat sources in the room (oven,
hairdryer, etc
the air exhaust hose is detached from the
appliance
filter clogged
filter clogged or dirty
an internal safety device prevents the
appliance from being restarted until
three minutes have elapsed since it was
last turned off
the appliance has a self diagnosis system
to identify a number of malfunctions.
Transport, filling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
Attention!
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will break down from lack of oil.
SOLUTION
plug into the outlet
wait for the current to return
call the toll free customer service number
position the air hose correctly, keeping it
as short and free of curves as possible to
avoid bottlenecks
check and remove any obstacles
obstructing air discharge
close doors, windows and curtains,
bearing in mind the "TIPS FOR CORRECT
USE" given above
minimize heat sources impact by setting
on low or unplugging unnecessary
sources
fit the air exhaust hose in the housing at
the back of the appliance
clean or replace the filter as described above
clean the filter as described above (fig. 8)
wait. This delay is part of normal
operation.
see the SELF-DIAGNOSIS chapter
14
(fig. 6).