SAFETY PRECAUTIONS This device is to be serviced only by properly qualified service personnel. Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy. PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...
SPECIFICATIONS ITEM DESCRIPTION MS-197H MODEL 230 Volts AC 50 Hz Power Requirement 1,000 Watts (4.5 A) Single phase, 3 wire grounded 700 Watts full microwave power (IEC705) Power Output 2,450 MHz Microwave Frequency 2M213 - 09 Magnetron 0 ~ 60 min.
CAUTIONS Unlike other appliances, the microwave oven is MICROWAVE RADIATION high-voltage and high-current equipment. Personnel should not be exposed to the Though it is free from danger in ordinary use, microwave energy which may radiate from the extreme care should be taken during repair. magnetron or other microwave generating device if it is improperly used or connection.
INSTALLATIONS BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY. INSTALLING EARTHING INSTRUCTIONS 1. Empty the microwave oven and clean inside it with This microwave oven is designed to be used in a fully a soft, damp cloth. Check for damage such as earthed condition.
OPERATING INSTRUCTIONS FEATURES Oven Front Plate Window Door Screen Door Seal Power Knob Timer Knob Door Open Button Safety Door Lock System Turntable Rotating Ring CONTROL PANEL Watt Defrost 0.1Kg 1. POWER CONTROL KNOB: Used in selected the desired power level for cooking. 2.
OPERATING SEQUENCE MICROWAVE COOKING 1. Open the oven door, place the food on the turntable in the oven, and close the oven door. 2. Set the microwave power selector to the desired power level. There are five power levels from 90W to MAX.
CIRCUIT DESCRIPTION • As the door is closed, the contact of MONITOR • 3.2 volts AC is generated from the filament winding of SWITCH opens. This switch creates the short circuit to the high voltage transformer. This 3.2 volts is applied blow fuse during operation under abnormal condition.