For 4-wire Direct Wire Connection, continue
to step 3.
4-wire direct wire connection: Go to
"4-Wire Direct Wire Connection
For 3-wire Direct Wire Connection, continue
to step 3.
3-wire direct wire connection: Go to
"3-Wire Direct Wire Connection.
4-Wire Direct Wire Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
3. Prepare your 4-wire cable for direct
connection
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1
remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
4. Prepare to connect neutral bond wire and
neutral wire
Remove center terminal block screw (B). Remove neutral bond
wire (E) from green external bond conductor screw (A).
5. Connect neutral bond wire and neutral wire
."
"
Connect neutral bond wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct wire
cable under center screw of terminal block (B). Squeeze hooked
ends together and tighten screw.
6. Connect ground wire
/
" (38 mm) from
1
Connect ground wire (green or bare) (F) of direct wire cable
2
under green external ground conductor screw (A). Tighten screw.
7. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Insert tab of terminal block
cover into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements."