To Fix The Unit On The Mounting Plate; Closing The Unit; To Re-Install The Front Grille - Daikin CTXA15A2V1BW Installer's Reference Manual

Hide thumbs Also See for CTXA15A2V1BW:
Table of Contents

Advertisement

9
|
Finishing the indoor unit installation

9.3 To fix the unit on the mounting plate

9.4 Closing the unit

9.4.1 To re-install the front grille

Installer reference guide
44
NOTICE
Do NOT bend refrigerant pipes.
Do NOT push the refrigerant pipes onto the bottom frame or the front grille.
2 Pass the drain hose and refrigerant piping through the wall hole and seal the
gap with a putty.
1 Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
2 Press the bottom frame of the unit with both hands to set it on the bottom
hooks of the mounting plate. Make sure that the wires do NOT get squeezed
anywhere.
Note: Take care that the interconnection cable does NOT get caught in the indoor
unit.
3 Press the bottom edge of the indoor unit with both hands until it is firmly
caught by the mounting plate hooks.
4 Secure the indoor unit to the mounting plate using 2 indoor unit fixing screws
M4×12L (accessory).
1 Install the front grille and firmly engage the 3 upper hooks.
2 Tighten the 2 screws and put the 2 screw covers back.
3 Re-install the flap.
4 Insert the wire harness back into the connector and secure it with the wire
clamp.
5 Close the front panel. Refer to
"9.4.4 To close the front
CTXA15+FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
4
panel" [
 45].
Daikin room air conditioner
4P518023-3K – 2022.05

Advertisement

Table of Contents
loading

Table of Contents