Spindle motor does not move
Motor no move
Check the FFC connection
between 24P and the loader.
Check whether "M5V"
(+5V) voltage is normal.
Check whether laser voltage
(1.9V for CD & 2.4V for DVD)
on L101 and L102
1.Whether voltage on pin102/pin103 of U1
varies between 2.4V and 3.3V (Pin102=3.3V
and Pin103=2.4V for CD; Pin102=2.4V and
Pin103=3.3V for DVD),
2.Whether peripheral components are eroded
or badly soldered.
Check opu focus
Check/Replace the loader
Go
Yes
Yes
Yes
Yes
Yes
4-1
No
Correct connection
No
Check the M5V power supply
No
Check/Replace Q103,Q104.
No
Check/Replace U1.
1.
Check U1 111pin FOCUS_PWM
No
signals
2.
If there are F+, F-, T+ and T-
signals output from U10.
FOCUS_PWN waveform

Trouble shooting chart