Download Print this page

Sennheiser HD 650 Instruction Manual page 3

High-definition open-back headphones
Hide thumbs Also See for HD 650:

Advertisement

EN English
Important safety information
t>
Read this instruction manual
carefully and completely
before using the product.
t>
Always
include this instruction manual
when
passing the product
on
to third parties.
t>
Do not use an
obviously
defective
product.
Preventing damage to health and accidents
t>
Protect
your
hearing from high
volume
levels. Permanent hearing
damage
may
occur
when
headphones
are
used at high
volume
levels
for
long periods
of
time.
Sennheiser
headphones
sound exceptionally good at
low
and
medium
volume
levels.
t>
The product
generates stronger
permanent magnetic fields
that could cause
inter-
ference
with cardiac
pacemakers,
implanted defibrillators
(I CDs) and other
implants.
Always
maintain
a
distance
of at
least
3.94"/10 cm
between the product
component
containing
the magnet and the
cardiac
pacemaker, implanted defibrillator,
or other
implant.
t>
Keep the product,
accessories and packaging
parts
out of
reach
of children and
pets to
prevent
accidents. Swallowing and choking
hazard.
t>
Do not use the product in
an environment that
requires
your special attention (e.g. when
per-
forming skilled
jobs).
Preventing damage to the product and malfunctions
t>
Always
keep the product dry
and
do not
expose
it to
extreme temperatures (hairdryer,
heater,
extended exposure to
sunlight,
etc.)
to
avoid corrosion or
deformation.
t>
Do not place
your
headphones
on a glass
dummy head,
chair armrest or similar objects for
long
periods
as
this
can widen the
headband
and
reduce the
contact
pressure
of
the headphones.
t>
Use
only attachments/accessories/spare
parts
supplied or
recommended by
Sonova Consumer
Hearing.
t>
Clean
the product
only with a soft,
dry
cloth.
t>
Use the product
with care and store
it in
a clean,
dust-free
environment.
Intended
use/Liability
These
open
dynamic headphones have been designed
for
home use
with
high-quality
audio
systems.
It is
considered
improper use
when
the product is used
for any application
not named in the
cor-
responding product
documentation. Sonova Consumer
Hearing
GmbH does
not
accept
liability
for
damage
arising
from misuse
or
improper use
of the product and
its
attachments/accessories.
Be-
fore
putting the
product
into
operation,
please
observe the
respective
country-specific
regulations.
Package
contents
1
HD
650 open,
dynamic headphones
1
connection cable with
1/4"
(6.35
mm)
stereo
jack plug, length
3
m
1
stereo
jack
adapter (1/4" (6.35
mm) to
3.5
mm)
1
instruction manual
Your Sennheiser HD 650
With
the HD
650, our engineers
have
followed
the
changes
in the listening habits
of
music lovers
and
the
way
in
which
they
experience sound.
In
spite of all purism and the
highest
demands
made
on
precise reproduction,
a slight change
in listening behavior has made itself felt.
Many
music
lovers now
want
to feel
the sound
more
and analyze
it less. The HD
650 captivates your senses
where you
used
to
be
a
mere
observer.
It
allows
total
submersion
in
an ocean of
music
where your
can completely forget your surroundings. Come and enjoy
this unique listening
experience!
Features
Top-of-the-range
open,
dynamic hi-fi
stereo
headphones
Systems with
narrow
tolerances(±
1 dB). hand-picked in pairs
High-quality titanium
silver
finish
Specially
developed
acoustic
mesh
for precise,
uniform
attenuation over the entire area
Specially
developed
detachable connection cable
made from highly
conductive OFC copper,
high
tensile
strength
due to para-aramid fiber
reinforcement,
with very
low handling noise
Extremely lightweight
aluminum voice coils ensure excellent
transient response
Exceptionally
comfortable
to
wear
due
to elliptical
design
adapted
to the
shape of
the
ears
Can
be
directly connected
to high-quality
stationary
hi-fi
components, especially SACO,
DVD-A,
Blu-ray, CD
players
and
DACs
for your Mac or
PC
for
HiRes music files
Fully
exploit
the
sound
potential
of your
HD
650 - with
the
Sennheiser
HOV
820 balanced
head-
phone
amplifier and a CH 660
P
or CH 650 S balanced connection cable
Illustrations for the following chapters can be found below the
cover
page.
mmm
Connecting,
putting
on and using
the headphones
t>
Select
the
suitable connection cable and,
if necessary,
an adapter for
the
audio source to which
you want to connect
the headphones
and change
the
connection cable as
described below:
1/4" (6.35
mm)
stereo
jack plug, unbalanced
(can also
be
connected to a 3.5
mm
stereo
jack
socket
by using the
supplied adapter)
*4.4
mm
stereo
jack plug, balanced
(Sennheiser CH 660
P,
optional accessory)
*XLR-4 connector,
balanced
(Sennheiser CH 650 S, optional accessory)
t>
Connect the
headphones
to your audio source.
t>
Put
on your
headphones
and then pull the ear cups down
until they rest
comfortably over
the
ears. Make sure you wear them the
right
way round by observing the
"R"
(right) and "L" (left)
markings
on
the
ear cup bands.
t>
For
optimum sound quality, ensure that
the
ear cups are
not
covered.
Ill
Replacing
the
ear pads
For reasons
of
hygiene,
you should
replace the
ear
pads from
time
to
time. Spare
parts
are available
from
your Sonova Consumer
Hearing partner. To find
a
partner in
your country, search at
www.sennheiser-hearing.com/service-support.
t>
Grasp
behind
the ear
pads
and
pull
them
up
and away
from
the ear cups.
t>
Place the new
ear pads onto
the
ear cups and attach
the
ear
pads
by
pressing firmly
around
them.
The headband padding can be replaced by the repair
service.
Please contact your Sonova Consumer
Hearing partner.
II
Changing
the
connection cable
t>
Make
sure
the "R"
(right) and
"L"
(left)
markings
on
the
connectors
match the markings
on
the
ear
cups.
The marking
on the connectors
must
point outward.
t>
Insert
the connector
until it locks into place
with an audible click.
Specifications
Frequency response
10
-41,000
Hz
(-10
dB)
Transducer principle
dynamic
Frequency
characteristic
diffuse-field
equalized
Nominal impedance
300 0
Sound
pressure level
at
1 kHz
103 dB
(1 V~,)
Long-term input
power
max.
500
mW
as per
EN
60-268-7
THO
<;
0.05
% (1
kHz, 1
V,ms)
Contact pressure
approx. 6.0
N
±
1.0 N
Ear
coupling
circum-aural, open
Weight
approx. 260 g (without cable)
Magnetic
field
strength at
the
surface
1,8 mT
Connector
6.35
mm
stereo
jack
plug
Adapter
1/4"
(6.35
mm)
stereo
jack plug
to 3.5
mm
stereo
jack
plug
Connection cable
Operating
temperature
Manufacturer declarations
Warranty
oxygen-free copper cable (OFC), 3
m
-10 'C
to +55
'C
Sonova Consumer
Hearing
GmbH gives a warranty of 24
months
on
this
product.
For
the current
warranty conditions,
please
visit our website at www.sennheiser-hearing.com/warranty or contact
your Sonova Consumer
Hearing partner.
For AUSTRALIA
and
NEW ZEALAND ONLY
Sonova
Hearing
Australia
Pty Ltd
provides a warranty of 24
months
on
these pro-
ducts.
For the
current warranty conditions, visit the Sonova Consumer
Hearing
website:
www.sennheiser-hearing.com/warranty.
Sonova Consumer
Hearing
goods come with guarantees
that
cannot
be
excluded
under
Australian
and
New
Zealand Consumer
law.
You are entitled to a
replacement
or
refund
for a
major
failure and
compensation for any other
reasonably
foreseeable
loss
or
damage.
You are also entitled
to have
the
goods
repaired
or
replaced if the
goods fail to
be
of acceptable quality and the
failure
does
not
amount to a
major failure.
This
warranty
is in
addition
to
other
rights
or
remedies under law. Nothing in this
warranty excludes,
limits
or
modifies
any
remedy
available
to the
consumer which
is
granted
by law.
To make
a claim
under
this
contract,
raise
a case via the Sonova Consumer
Hearing
website:
www.sennheiser-hearing.com/service-support.
All expenses of claiming
the
warranty will be
borne by the person making
the claim.
Sonova Consumer
Hearing international
warranty
is provided by:
Sonova
Hearing
Australia
Pty Ltd
(ABN 82651492929)
The
Zenith,
Level 14, Tower
A, 821
Pacific Highway,
Chatswood
New
South
Wales 2067, Australia.
In compliance
with
the following
requirements
EU
declaration of
conformity
RoHS Directive
(2011/65/EU)
The
declaration
is
available at www.sennheiser-hearing.com/download.
UK declaration of
conformity
RoHS Regulations (2012)
Notes on
disposal
EU:
WEEE
Directive
(2012/19/EU)
UK:
WEEE Regulations (2013)
The symbol of the crossed-out wheeled bin on the product, the battery/rechargeable
battery (if applicable) and/or the packaging indicates that these products must not be
CE
UK
CA
)16
-
disposed of with normal household waste, but must be disposed of separately at the end of their oper-
ational
lifetime. For
packaging disposal, observe the legal
regulations
on waste segregation applicable
in your country.
Improper
disposal of packaging materials can harm your health and the environment.
The
separate collection of waste electrical and electronic equipment, batteries/rechargeable
batteries
(if applicable) and
packagings is used to
promote
the reuse
and
recycling
and
to prevent
negative
effects on your
health
and
the
environment, e.g. caused by
potentially hazardous
sub-
stances contained
in these products.
Recycle electrical and electronic equipment and
batteries/
rechargeable
batteries at the end of their operational
lifetime in
order
to make
contained
recyclable
materials usable
and
to
avoid
littering
the environment.
If
batteries/rechargeable batteries can
be removed
without damaging them
,
you are obliged to
dispose
of them separately (for the safe
removal
of
batteries/rechargeable
batteries, see the
instruction manual
of the
product). Handle lithium-containing batteries/rechargeable
batteries
with special care, as they
pose
particular
risks,
such as the
risk
of
fire
and/or
the risk
of
ingestion
in the
case of coin
batteries. Reduce
the generation of battery waste as
much
as possible by
using
longer-life batteries
or
rechargeable batteries.
Further information
on the
recycling
of
theses
products can be obtained
from
your
municipal
admin-
istration, from the municipal
collection
points,
or
from
your Sonova Consumer
Hearing partner.
You
can also
return
electrical or electronic equipment to distributors who
have
a take-back obligation.
Herewith
you
make
an
important
contribution to the protection of the environment and public
health.

Advertisement

loading