ACR Electronics RCL-100 LED Product Support Manual

Remote control searchlight system

Advertisement

Quick Links

PRODUCT SUPPORT MANUAL
RCL-100 LED //
Remote Control Searchlight System
Model No.: RCL-100 LED
Product No.: 1950, 1951, 1952, 1953
Y1-03-0321 Rev. C
ACR Electronics, Inc., // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6603
Y1-03-0321A
i
T: +1 (954) 981-3333 // F: +1(954) 983-5087 // www.acrartex.com

Advertisement

Table of Contents
loading

Summary of Contents for ACR Electronics RCL-100 LED

  • Page 1 Remote Control Searchlight System Model No.: RCL-100 LED Product No.: 1950, 1951, 1952, 1953 Y1-03-0321 Rev. C ACR Electronics, Inc., // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6603 Y1-03-0321A T: +1 (954) 981-3333 // F: +1(954) 983-5087 // www.acrartex.com...
  • Page 2: Table Of Contents

    SECTION 2 - SEARCHLIGHT __________________________ 3 SECTION 3 - URP-102 POINT PAD™ ___________________ 4 SECTION 4 - URC-103 MASTER CONTROLLER ___________ 9 APPENDIX A - RCL-100 LED SPECIFICATIONS (with URC- 103 Controller) __________________________________ 14 APPENDIX B - USER REPLACEABLE PARTS _____________ 15...
  • Page 3: Section 1 - General

    SECTION 1 - GENERAL The RCL-100 LED was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-100 LED Searchlight System contains a narrow beam searchlight that produces 220,000 peak candle power by combining a 9 LED array with unique optical quality reflectors.
  • Page 4: Section 3 - Urp-102 Point Pad

    the unit. When mounting, be sure that the Searchlight is able to rotate 360° without hitting any obstructions. For the drilling hole pattern, refer to the Searchlight Mounting Template supplied with the RCL- 100 LED searchlight. DURING INSTALLATION OR OTHERWISE, DO NOT TURN THE LIGHT BY HAND, OR FORCE IT TO TURN MANUALLY AT ANY TIME.
  • Page 5 coax cable from the Master Controller can be routed to this location. Generally, the Point Pad™ should be mounted in a protected area. Note that the Point Pad™ is water resistant, not waterproof. Install the surface mount Point Pad™ by drilling 3 holes in the dashboard location using the Point Pad™...
  • Page 6 BLUE IS NEGATIVE (-) ORANGE IS POSITVE (+) BROWN, BLACK, WHITE, YELLOW, GREEN AND RED are CONTROL WIRES. If any of these are wired to the vessel power, the unit will be irreparably damaged. Damage as a result of incorrect wiring will not be warranted. ACR can evaluate the problem and ascertain whether the unit had a product failure or a breakdown due to incorrect wiring by the installer.
  • Page 7 Figure 1 - Point Pad™ Connection Block Diagram Figure 2 - URP-102 Point Pad™ Functions URP-102 Point Pad Functions Press the ON/OFF button to turn the lights ON or OFF.  Press the SPEED button to toggle between High and Low rotation ...
  • Page 8 NOTE: XRCiZ™ feature for the RCL-100 LED is only available when paired with a URC-103 Master Controller. Figure 3 - URP-102 Point Pad™ Surface Mount Case Figure 4 - URP-102 Point Pad™ Flush Mount Case Y1-03-0321C...
  • Page 9: Section 4 - Urc-103 Master Controller

    Figure 5 - URP-102 Point Pad™ Surface Mount Case with gasket and Flush Mount Case with gasket SECTION 4 - URC-103 MASTER CONTROLLER Mounting The Master Controller can be mounted in any position near the Searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad™...
  • Page 10 Master Searchlight Power Source Function Controller Wire Cable Wire Lead ORANGE +12 VDC or +24 Power VDC** BLUE (-ve) Ground Ground Yellow Yellow Lamp Power Green Green Lamp Power White White Down Black Black Right Brown Brown Left Table 1 WARNING: The ORANGE wire must be fused with a 5 amp fuse in the Master Controller's in-line fuse-holder.
  • Page 11 Maximum Cable Length Wire Size 12v System 24v System #8 AWG 25 ft. 100 ft. #10 AWG 15 ft. 60 ft. #12 AWG 10 ft. 40 ft. Table 2 Function The URC-103 Master Controller is designed to perform up to six different duties on searchlights, winches, and other electrical devices.
  • Page 12 NOTE: The Searchlight should not be covered while the XRCiZ™ feature is enabled. The Master Controller also has a searchlight motor timeout feature. If a Point Pad™ rotation switch (right or left) is continuously engaged for more than 50 seconds, the Master Controller will interrupt the operation until the Point Pad™...
  • Page 13 Figure 7 - URC-103 Master Controller Y1-03-0321C...
  • Page 14: Appendix A - Rcl-100 Led Specifications (With Urc-103 Controller)

    APPENDIX A - RCL-100 LED SPECIFICATIONS (with URC-103 Controller) Specification 12V or 24V Rated voltage (Volt) 12 - 24 VDC Rated current (A) 5 A maximum Applicable lamp 9 LED Array Peak beam candle 220,000 power (candela) Horizontal 7°, Beam spread (degrees) Vertical 5°...
  • Page 15: Appendix B - User Replaceable Parts

    APPENDIX B - USER REPLACEABLE PARTS ACR/RCL-100 LED Item ACR Part Description Quantity Number Number Front Glass HRMK 1300 Front Frame HRMK 2101 Window Weather Strip HRMK 1201 Screw M4x18 HRMK 1600 Washer M408 HRMK 9301 Gasket of front frame...
  • Page 16: Appendix C - Product Components

    APPENDIX C - PRODUCT COMPONENTS Product No. 1951 - RCL-100 LED 12-24 V Searchlight - Installation Kit includes: Description Quantity ACR Part Number Searchlight, RCL-100 LED, 12-24 A3-06-2952 Kit, Nylon Washers (4) A3-06-1940 A1-03-0220 Connector, “F” Cable, Coaxial 15ft A2-07-0002-6...
  • Page 17 Gasket, Flush Mount A1-25-0140-2 U Clamp A1-17-1366 Nuts, Nylon-lock A1-05-0776 Washers A1-05-0777 Adapter Plate, Flush mount A1-18-1871 Adapter Plate, Surface mount A1-18-1892 Instruction Sheet, Point Pad™ Y1-06-0179 Mounting Templates Y1-03-0138-1 Product No. 1929.1 - Wiring Kit RCL-50 / 100 series searchlights includes: Description Quantity...
  • Page 18: Appendix E - Warranty, Notices

    1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR.

This manual is also suitable for:

1950195119521953

Table of Contents