134 mm
REMOTE CONTROL DEVICE TECHNICAL DATA
Power supply
Electrical absorption
Operating temperature
Storage temperature
Bus wire length and cross-sectional area
NOTE: IN ORDER TO AVOID INTERFER-
ENCE PROBLEMS, USE A SHIELDED CA-
BLE OR TWISTED PAIR CABLE.
Buff er memory
Conformity
LVD 2006/95/EC - EMC 2004/108/EC
Electromagnetic interference
Electromagnetic emissions
Conformity to standards
Temperature sensor
Resolution degree
PRODUCT FICHE
SUPPLIER'S NAME
SUPPLIER'S MODEL IDENTIFIER
Class of the temperature control
Contribution to seasonal space heating energy effi ciency in %
Adding an outdoor sensor:
Class of the temperature control
Contribution to seasonal space heating energy effi ciency in %
In a 3-zones system with 2 room sensors
Class of the temperature control
Contribution to seasonal space heating energy effi ciency in %
62 /
OUTDOOR SENSOR
16 mm
BUS
max. < 0.5W
-10 to 60°C
-20 to 70°C
max. 50 m
min. 0.5 mm²
Position the outdoor sensor on the north-facing wall of the
2 h
building, at least 2.5 m from the ground and away from
direct sunlight.
Remove the cover (fi g. A) and install the sensor using the
EN 60730-1
rawl plug and screw provided (fi g. B).
EN 60730-1
Make the connection using a 2x0.5 mm
Maximum connection length 50 m.
EN 60730-1
Connect the wire to the terminal (fi g. C) by introducing it
NTC 5 k 1%
from the lower part after creating a suitable passage.
0.1°C
Place the sensor cover back in the correct position.
A
B
ARISTON
Sensys
V
+3%
VI
+4%
VIII
+5%
C
2
cable.
Outdoor Sensor
II
+2%
--
--
--
--