Download Print this page
Chromalox NWHO-33015 Installation And Renewal Parts Identification

Chromalox NWHO-33015 Installation And Renewal Parts Identification

Nwho-3 series circulation heaters

Advertisement

Quick Links

RENEWAL PARTS IDENTIFICATION
1-3/8" Conduit
Openings
8-1/32"
1" Pipe
Outlet
A B
C
1" Pipe
Inlet
WARNING: This heater is not intended for use in haz-
ardous atmospheres where flammable vapors, gases,
liquids or other combustible atmospheres are present
as defined in the National Electrical Code. Failure to
comply can result in explosion or fire.
The NWHO-3 series is a general-purpose regular and fuel oil solu-
tion circulation heater intended for use indoors. It is designed for 150
psig at 550˚F per ANSI standards.
The 3 steel-sheathed tubular elements are centered in a 3" diame-
ter steel heating chamber and welded to a removable steel flange. The
assembly is surrounded by 1-1/2" insulation and sheet metal jacket.
WARNING: Hazard of Shock. Disconnect all power
before installing heater.
1. Vertical mounting (Preferred) —
When the heater is vertically mounted, the terminal housing will be
at the top of the heater. The inlet pipe will be located on the side
near the bottom of the heater and the outlet pipe at the top.
The axis of the chamber will be in a vertical position as in the
photo above and as in Figure A.
Correct
© 2010 Chromalox, Inc.
Chromalox
Installation
and
12-5/16"
Type NWHO-3 Series Circulation Heaters
(for Regular and Fuel Oil Heating)
Thermostat
Type AR
Mounting Lugs
3/8" - 16
Threaded Holes -
1-1/2" Deep
1-1/4" Centers
6-1/8"
Incorrect
Figure A — Vertical Mounting
®
Specifications — Table A
Model
Volts
NWHO-33015
NWHO-34515
NWHO-36015
240 or 480
NWHO-37515
NWHO-39015
NWHO-30315
NWHO-30415
240 or 480
NWHO-30615
GENERAL
Depending upon the order specifications, the NWHO-3 may or
may not be factory equipped with AR or other Chromalox thermostat.
Such thermostats function to control outlet temperatures and to limit
internal temperatures under abnormal flow conditions. These controls
do not fail safe.
CAUTION: Users should install adequate back-up controls
and safety devices with their electric heating equipment.
Where the consequences of failure may be severe, back-
up controls are essential. Although the safety of installa-
tion is the responsibility of the user, Chromalox will be
glad to make equipment recommendations.
INSTALLATION
Note: A drain pipe located at the bottom of the heater should be
provided and enough room left, when mounting heater, to allow
draining the heater.
2. Horizontal Mounting (Optional) —
When mounting heater horizontally, inlet and outlet pipes must be
up. In any other position, heater cannot be purged of air, and ele-
ments may be seriously damaged. (See Figure B.)
SERVICE REFERENCE
4
DIVISION
SECTION
SALES
(Supersedes PE406-4)
REFERENCE
FEBRUARY, 1999
DATE
Regular Oil Heaters
Phase
kW
W/In
2
3
32-15/16
4.5
32-15/16
1 or 3
6
23
42-15/16
s s
7.5
55-7/16
9
55-7/16
Fuel Oil Heaters
3
32-15/16
1 or 3
4
15
42-15/16
s s
6
55-7/16
Correct
Incorrect
Figure B — Horizontal Mounting
NHWO
PE406-5
161-048710-001
Dimensions (In.)
A
B
C
22-1/2
16-1/2
22-1/2
16-1/2
32-1/2
26-1/2
45
39
45
39
22-1/2
16-1/2
32-1/2
26-1/2
45
39

Advertisement

loading

Summary of Contents for Chromalox NWHO-33015

  • Page 1 NWHO-30315 NWHO-30415 NWHO-30615 GENERAL may not be factory equipped with AR or other Chromalox thermostat. Such thermostats function to control outlet temperatures and to limit internal temperatures under abnormal flow conditions. These controls do not fail safe. CAUTION: Users should install adequate back-up controls and safety devices with their electric heating equipment.
  • Page 2 240V, 480V 3Øs s Note: Dotted lines indicate “customer furnished.” However, Thermostat could have been furnished by Chromalox if so specified on the order. 1. Do not heat solutions that are corrosive to the heating element sheath or the heating chamber.
  • Page 3 Regular Oil Heater Model Volts Phase NWHO-33015 NWHO-33015 NWHO-33015 NWHO-33015 NWHO-34515 NWHO-34515 NWHO-34515 NWHO-34515 NWHO-36015 NWHO-36015 NWHO-36015 NWHO-36015 NWHO-37515 NWHO-37515 NWHO-37515 NWHO-37515 NWHO-39015 NWHO-39015 NWHO-39015 NWHO-39015 Note: When ordering parts for Model Numbers suffixed by “XX” or any other letters not specifically identified on this instruction sheet, order Renewal Parts on special order basis, giving name of part, part number, model number and description.
  • Page 4 Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. 2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com 99 - 050 TA - P9 - EF Litho in U.S.A.

This manual is also suitable for: