12.5.7. Dew Prevention control
• To prevent dew formation at indoor unit discharge area.
• This control will be activated if:-
- Cooling mode or Quiet mode.
- Remote Control setting temperature is less than 25°C.
- Fan speed is at CLo or QLo.
- Room temperature is constant (±1°C) for 30 minutes.
- Compressor is continuously running.
• Fan speed and angle of horizontal louver (vertical airflow angle) will be adjusted accordingly in this control.
- Fan speed will be increased slowly if the unit is in quiet mode but no change in normal cooling mode.
- The angle of horizontal louver will be changed as below figure.
Operation mode
Cooling, Soft Dry
Note:
A = Normal operation angle of rotation
B = Dew prevention angle of rotation
Horizontal Louver Angle
During Anti-Dew condensation prevention, the horizontal louver angle in Auto-control are as below figure.
During Anti-Dew condensation prevention, the horizontal louver angle in Manual control are as below figure.
Airflow direction auto-control
A
12° ~ 32°
B
20° ~ 30°
36
Airflow direction manual control
12°, 15°, 20°, 26°, 32°
22°, 24°, 26°, 28°, 30°