Refrigerant System Diagram - Mitsubishi Electric PUZ-ZM35VKA2 Service Manual

Split-type, heat pump air conditioners
Table of Contents

Advertisement

REFRIGERANT SYSTEM DIAGRAM

9
Stop valve
(with service port)
Refrigerant GAS pipe
connection(1/2F)
Linear
expansion valve B
Stop valve
Refrigerant LIQUID pipe
connection(1/4F)
OCH751
Solenoid valve
(4-way valve)
Strainer
#50
Strainer
#100
Power
receiver
Strainer
#100
23
Charge plug
Muffler
High pressure
switch 63H
Thermistor TH4
<Discharge>
Thermistor TH33
<Comp. surface>
Muffler
Compressor
Linear expansion valve A
Unit: mm (inch)
Thermistor TH7
Heat exchanger
<Ambient>
Thermistor TH6
<2-phase pipe>
Thermistor TH3
<Liquid>
Strainer
#100
Refrigerant flow in cooling
Refrigerant flow in heating
Distributor