LG LP073HDUC/00 Owner's Manual page 12

Table of Contents

Advertisement

Available languages

Available languages

Installation
• UNIT INSTALLATION
1. Remove the shipping screw from the ventilation door.
2. Remove the front gille by pulling it out at the bottom
to release it, then lift it up along the unit top front.
3. Remove cover by removing 3 screws from front.
4. Connect accessory power supply cord, and fix power
cord to basepan with screws.
ELECTRIC HEATER RATING
(CONFIGURATION BASED ON POWER CORD)
HEATER
POWER CORD
VOLTAGE
AYUH2115
230/208
2 400/2 300 W
AYUH2120
230/208
3 300/3 200 W
AYUH2130
230/208
4 700/4 600 W
5. Replace cover with screws. Tighten securely.
6. Slide the unit into the wall sleeve and secure with
4 screws through the unit flange holes.
7. Reinstall the front grille by hooking the top over the
unit top, then pushing it in at the bottom.
12 Room Air Conditioner
HEATER
MAX.
WATTS
CURRENT
FUSE SIZE
10.5/11.2 A
15 A
14.5/15.5 A
20 A
20.6/22.3 A
30 A
MIN.CIRCUIT
AMPACITY
14.5 A
19.8 A
28.3 A

Advertisement

Chapters

Table of Contents
loading

Table of Contents