Installation Procedure - Bosch DKE9465MUC Installation Instructions Manual

36" wall mount chimney hood 500 series - stainless steel
Hide thumbs Also See for DKE9465MUC:
Table of Contents

Advertisement

Available languages

Available languages

Power Requirements

Installation Procedure

1) Unpack Hood
2) Prepare Ductwork
3) Prepare Wall
English 4
of weight the wall must support. Note: At least one screw must be installed
through a stud.
Table 1: Minimum Weight Requirements
Size
With Recirculation Kit
30" (760 mm)
140 lbs (63.5 kg)
36" (900 mm)
155.5 lbs (70.5 kg)
Electrical Specifications: 120V AC, 60Hz. 15A Branch Circuit
WARNING:
switch power off at the service panel and lock the panel to prevent the
power from being switched on accidentally.
Pull hood from outer packaging. Remove and discard all packaging materials.
Remove filter and set aside (See Use and Care manual for removal instructions).
Install one-way damper so that the flap opens up. Press damper down into the
blower outlet until it is snug. Note: verify that the flap opens up (toward the ceiling)
before continuing. See "Prepare Ductwork" on page 4. If necessary, install transi-
tion, thermal break and additional backdraft damper.
See "General Information" on page 2 for recommended installation height and
"Mounting Requirements" on page 3 for information on wall requirements.
Once the preferred height is determined, draw a line at the vertical centerline of
the cooking appliance.
Use the installation template to locate and mark the screw holes. Drill 1/4" (6 mm)
pilot holes (4 holes for hood screws and 2 holes for chimney screws). Install plugs
in screw holes so that they are flush with the wall.Install two screws in top hood
screw holes. Leave about 3/8" (6 mm) of each screw exposed.
Without Recirculation Kit
126 lbs (57.1 kg)
142 lbs (64.5 kg)
To avoid electrical shock hazard, before installing,
Figure 2: Prepare Ductwork