NOTICE is used to address practices not related to physical injury. Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual. www.insinkerator.com/foodservice Part No. 15330 Rev. B...
The warranty includes parts and labor, provided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.
US listed for use ® flow to the disposer will slow to one gallon per minute if with InSinkErator Foodservice Disposers. See Table 1 there is not food waste present in the grinding chamber. for approved disposer and control center combinations and Table 2 for electrical specifications.
Mounting the Control Center/Plumbing Connections MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical 9-7/8" (250.8 mm) position (door hinge is on the left). See Figure 1. 8-1/4"...
Electrical Connection Diagrams M1/M3 M4/M6 M3/M4 Motor Leads Motor Leads 24V Water Solenoid 24V Water Solenoid 1 GPM Flow Control 1 GPM Flow Control Disposer Disposer 24V Water Solenoid 24V Water Solenoid 7 GPM Flow Control 7 GPM Flow Control Pre-wired in Pre-wired in panel to...
Electrical Connections ELECTRIC SHOCK • Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. • All installation work must conform to local plumbing and electrical codes. •...
Operating Instructions/AquaSaver Adjustment OPERATING INSTRUCTIONS NOTE: This feature is set in the manual position at the factory. To activate the automatic timed disposer TO START shut-off, disconnect the electric power to the control 1. Check to ensure disposer is free of foreign objects. center, then open the control center door.
Troubleshooting PERSONAL INJURY ELECTRICAL SHOCK/PROPERTY DAMAGE • Allow only trained personnel to operate disposer. • Troubleshooting other than what is recommended in this section should only be performed by • Use baffles and guarding to avoid splashing and qualified service personnel. ejection of materials.
• Black wires = Line voltage (120 V) control. AS-101K-5 120 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (208 - 240 V) control. AS-101K-6 208/240 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (208 - 240 V) control. AS-101K-7 208/240 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (380 - 460 V) control. AS-101K-8 380/460 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.