DISPOSER CONTROL CENTER
Installation Manual
Model AS-101K
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE is used to address practices not related to physical injury.
Please be certain that the person who installs or uses this appliance carefully reads
and understands the Safety Instructions contained in this manual.
www.insinkerator.com/foodservice
Part No. 15330 Rev. B

Advertisement

Table of Contents
loading

Summary of Contents for InSinkErator AquaSaver AS101

  • Page 1 NOTICE is used to address practices not related to physical injury. Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual. www.insinkerator.com/foodservice Part No. 15330 Rev. B...
  • Page 2: Table Of Contents

    The warranty includes parts and labor, provided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.
  • Page 3: Introduction/Features

    US listed for use ® flow to the disposer will slow to one gallon per minute if with InSinkErator Foodservice Disposers. See Table 1 there is not food waste present in the grinding chamber. for approved disposer and control center combinations and Table 2 for electrical specifications.
  • Page 4: Mounting The Control Center/Plumbing Connections

    Mounting the Control Center/Plumbing Connections MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical 9-7/8" (250.8 mm) position (door hinge is on the left). See Figure 1. 8-1/4"...
  • Page 5: Electrical Connection Diagrams

    Electrical Connection Diagrams M1/M3 M4/M6 M3/M4 Motor Leads Motor Leads 24V Water Solenoid 24V Water Solenoid 1 GPM Flow Control 1 GPM Flow Control Disposer Disposer 24V Water Solenoid 24V Water Solenoid 7 GPM Flow Control 7 GPM Flow Control Pre-wired in Pre-wired in panel to...
  • Page 6: Electrical Connections

    Electrical Connections ELECTRIC SHOCK • Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. • All installation work must conform to local plumbing and electrical codes. •...
  • Page 7: Operating Instructions/Aquasaver Adjustment

    Operating Instructions/AquaSaver Adjustment OPERATING INSTRUCTIONS NOTE: This feature is set in the manual position at the factory. To activate the automatic timed disposer TO START shut-off, disconnect the electric power to the control 1. Check to ensure disposer is free of foreign objects. center, then open the control center door.
  • Page 8: Troubleshooting

    Troubleshooting PERSONAL INJURY ELECTRICAL SHOCK/PROPERTY DAMAGE • Allow only trained personnel to operate disposer. • Troubleshooting other than what is recommended in this section should only be performed by • Use baffles and guarding to avoid splashing and qualified service personnel. ejection of materials.
  • Page 9: Model No. As-101K-5 (120V, 1 Phase, 1/2 - 2 Hp)

    • Black wires = Line voltage (120 V) control. AS-101K-5 120 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
  • Page 10: Model No. As-101K-6 (208/240V, 1 Phase, 1/2 - 2 Hp)

    • Black wires = Line voltage (208 - 240 V) control. AS-101K-6 208/240 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
  • Page 11: Model No. As-101K-7 (208/240V, 3 Phase, 1/2 - 10 Hp)

    • Black wires = Line voltage (208 - 240 V) control. AS-101K-7 208/240 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
  • Page 12: Model No. As-101K-8 (380/460V, 3 Phase, 1/2 - 10 Hp)

    • Black wires = Line voltage (380 - 460 V) control. AS-101K-8 380/460 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.