Panasonic CS-RZ35WKRW Service Manual page 15

Hide thumbs Also See for CS-RZ35WKRW:
Table of Contents

Advertisement

Indoor
Outdoor
Indoor Operation Range
Outdoor Operation Range
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.
5.
TCSPF and HSPF only indicate the value of Residential Mixed Zone.
6.
Sound pressure level specification is measured according to JIS C9612 [<70 dB(A)].
7.
Specifications are subjected to change without prior notice for further improvement.
Model
POS (EAN)
Model
POS (EAN)
Maximum °C (°F)
Cooling
Minimum °C (°F)
Maximum °C (°F)
Heating
Minimum °C (°F)
Maximum °C (°F)
Cooling
Minimum °C (°F)
Maximum °C (°F)
Heating
Minimum °C (°F)
15
CS-RZ25WKRW
5025232912121
CU-RZ25WKR
5025232913169
Dry Bulb
32 (89.6)
16 (60.8)
30 (86.0)
16 (60.8)
46 (114.8)
-10 (14.0)
24 (75.2)
-15 (5.0)
Wet Bulb
23 (73.4)
11 (51.8)
-
-
26 (78.8)
-
18 (64.4)
-